Removal and replacement procedures 33
6.
Remove the fan.
To replace the component, reverse the removal procedure.
Fan cage
IMPORTANT:
When installing or replacing server components, one or more fans might need to
be removed. To prevent an orderly or immediate server shutdown, HP highly recommends
powering down the server during these procedures. To determine if powering down is required,
see the specific procedure.
To remove the component:
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
Remove the tower bezel
" on page
27
).
o
For rack models, if installed, remove the security bezel (on page
27
).
2.
Power down the server (on page
26
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Do one of the following:
o
For tower models, place the server on a flat, level surface with the access panel facing up.
o
For rack models, extend the server from the rack (on page
28
).
5.
Remove the access panel ("
Access panel
" on page
29
).
6.
Remove the air baffle ("
Air baffle
" on page
30
).