Removal and replacement procedures 41
Power supply module
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
Remove the tower bezel
" on page
27
).
o
For rack models, if installed, remove the security bezel (on page
27
).
2.
Power down the server (on page
26
).
3.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
4.
Access the product rear panel.
5.
If removing a DC power supply, first remove the grounding wire.
6.
Remove the power supply.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
To replace the component, reverse the removal procedure.
Power supply backplane
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1.
Do one of the following:
o
For tower models, open and remove the bezel ("
Remove the tower bezel
" on page
27
).
o
For rack models, if installed, remove the security bezel (on page
27
).