Hardware options installation 58
For cable routing information, see "Optical drive cabling (on page
89
)."
15.
Install fan1 ("
Install the fan modules and the fan blank
" on page
31
).
16.
If removed, install the RPS rear blank.
17.
Install the full-length PCI expansion cards that were removed ("
Installing an expansion board
" on page
63
).
18.
Install the system air baffle (on page
28
).
19.
If removed, install the PCI air baffle ("
PCI air baffle option
" on page
38
).
20.
Install the access panel (on page
26
).
21.
Return the server to an upright position.
22.
Install the front bezel (on page
25
).
23.
Connect each power cord to the server.
24.
Connect each power cord to the power source.
25.
Power up the server (on page
23
).
FBWC options
The server supports FBWC options:
FBWC consists of a cache module and a capacitor pack. The DDR cache module buffers and stores
data being written by the controller. When the system is powered on, the capacitor pack charges fully
in about 5 minutes. In the event of a system power failure, a fully charged capacitor pack provides
power for up to 80 seconds. During that interval, the controller transfers the cached data from DDR
memory to flash memory, where the data remains indefinitely or until a controller retrieves the data.
CAUTION:
The cache module connector does not use the industry-standard DDR3 mini-DIMMs.
Do not use the controller with cache modules designed for other controller models, because the
controller can malfunction and you can lose data. Also, do not transfer this cache module to an
unsupported controller model, because you can lose data.