Removal and replacement procedures 32
4-bay LFF hot-plug drive cage
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
To remove the component:
1.
Power down the server (on page
25
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Place the server on its side.
4.
Remove the access panel (on page
25
).
5.
Remove the front bezel (on page
26
).
6.
Remove all drives ("
Hot-plug drive
" on page
31
).
7.
Remove all drive blanks ("
Hot-plug drive blanks
" on page
30
).
8.
If installed, remove the PCI air baffle (on page
27
).
9.
Remove the system air baffle (on page
28
).
10.
Disconnect the Mini-SAS cable and the power cable from the drive backplane.
11.
Disconnect the hard drive power good cable from the system board. Hard drive power good cable is
attached to the drive cage by default.
12.
Remove the LFF hot-plug drive cage:
o
Box 1
Summary of Contents for ProLiant ML110 Gen9
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 18: ...Illustrated parts catalog 18 ...
Page 22: ...Illustrated parts catalog 22 ...
Page 96: ...Cabling 96 FBWC module on a P840 controller HP Smart Storage Battery cabling ...
Page 98: ...Cabling 98 Optional system upgrade fan 92 x 38 mm PCI fan ...
Page 101: ...Cabling 101 Front I O cabling Front USB 3 0 cabling ...