Specifications 102
Specifications
Environmental specifications
Specification
Value
Temperature range*
—
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Nonoperating
-30
°
C to 60
°
C (-22
°
F to 140
°
F)
Relative humidity
(noncondensing)
—
Operating
Minimum to be the higher (more moisture) of
-12°C (10.4°F) dew point or 8% relative
humidity
Maximum to be 24°C (75.2°F) dew point or
90% relative humidity
Nonoperating
5% to 95%
38.7
°
C (101.7
°
F), maximum wet bulb
temperature
* All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per
1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C
per hour (36°F per hour). The upper limit and rate of change might be limited by the type and number of
options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of
1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3048 m
(10,000 ft).
•
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F
per every 410 ft) above 900 m (2953 ft) to a maximum of 3048 m (10,000 ft).
The approved hardware configurations for this system are listed on the HP website
(
http://www.hp.com/servers/ASHRAE
).
Server specifications
Specification
Value
Dimensions (with feet/bezel)
—
Height
44.00 cm (17.32 in)
Depth
48.05 cm (18.92 in)
Width
19.50 cm (7.68 in)
Weight (approximate)
—
Maximum (all drives, power supplies,
and processors installed)
24.9 kg (55.00 lbs)
Summary of Contents for ProLiant ML110 Gen9
Page 13: ...Customer self repair 13 ...
Page 14: ...Customer self repair 14 ...
Page 15: ...Customer self repair 15 ...
Page 18: ...Illustrated parts catalog 18 ...
Page 22: ...Illustrated parts catalog 22 ...
Page 96: ...Cabling 96 FBWC module on a P840 controller HP Smart Storage Battery cabling ...
Page 98: ...Cabling 98 Optional system upgrade fan 92 x 38 mm PCI fan ...
Page 101: ...Cabling 101 Front I O cabling Front USB 3 0 cabling ...