System Unit
Dimensions
(HxWxD)
(with feet)
10.5 x 8.3 x 10.2 in (26.7x 21.0 x 26.0 cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
21.16 lb (9.6 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
13.18 lb (5.98 kg)
Input Requirements
(per power supply)
Rated Line Voltage
100 -- 127 VAC,
200 - 240 VAC
Rated Input Current
3.5 A (at 110 VAC),
2 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
191.4 W (at 100 VAC),
184.9 W (at 200 VAC)
BTU Rating
Maximum
247.055 BTU/hr (at 100 VAC),
274.505 BTU/hr (at 200 VAC)
Power Specifications
To review typical system power ratings use the Power Advisor which is
available via the online tool located at URL:
http://www.hp.com/go/hppoweradvisor
Power Supply Output
(per power supply)
Rated Steady-State Power 150 W (at 100 VAC),
150 W (at 200 VAC)
Maximum Peak Power
200 W (at 100 VAC),
200 W (at 200 VAC
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 35°C (95°F).
Non-operating
10 to 90% relative humidity (Rh), 28°C
5 to 95% relative humidity (Rh), 38.7°C
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
Acoustic Noise
(Fully Loaded)
Idle
L WAd
3.9 BELS
L pAm
22.3 dBA
QuickSpecs
HP ProLiant MicroServer
Technical Specifications
DA - 13716 Worldwide — Version 22 — December 9, 2013
Page 20