Part Number
630295-001
Operational Input Voltage Range
(Vrms)
100 to 127 and 200 to 240 V auto ranging
Frequency Range
(Nominal) (Hz)
50 to 60 Hz
Nominal Input Voltage (Vrms)
100
115
208
220
230
240
Max Rated Output Wattage Rating
150
150
150
150
150
150
Nominal Input Current (A rms)
N/A
3.5
N/A
2
2
N/A
Max Rated Input Wattage Rating (Watts)
191.4
N/A
N/A
N/A
184.9
N/A
Max. Rated VA (Volt-Amp)
N/A
N/A
N/A
N/A
N/A
N/A
Efficiency (%)
70%
70%
N/A
N/A
70%
N/A
Power Factor
N/A
0.9
N/A
N/A
0.9
N/A
Leakage Current (mA)
N/A
3.5
N/A
N/A
3.5
N/A
Maximum Inrush Current (A peak)
N/A
No component
was damaged
and input fuse
shall not blow
N/A
N/A
No component
was damaged
and input fuse
shall not blow
N/A
Maximum Inrush Current duration (mS)
N/A
N/A
N/A
N/A
N/A
N/A
To review typical system power ratings use the Active Answers HP Power Advisor which is available via the online tool located at URL:
http://www.hp.com/go/hppoweradvisor
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
QuickSpecs
HP ProLiant MicroServer
Power Specifications
DA - 13716 Worldwide — Version 22 — December 9, 2013