Cabling 94
o
Hard drive status LEDs are not supported.
o
Hard drive thermal status monitoring is not supported.
o
Hot-plug operation is not supported.
•
Because only one drive bay is enabled, all remaining drives can be removed.
For proper thermal cooling, install blanks in all bays that do not have a drive installed. Order a sufficient
number of 6.35-cm (2.5-in) or 8.89-cm (3.5-in) hard drive blank option kits from an HP authorized
reseller. For more information, see the server maintenance and service guide.
•
The standard SATA driver is included with supported operating systems. No additional driver is
required.
To install the component:
1.
Power down the server (on page
23
).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Extend the server from the rack (on page
23
).
4.
Remove the access panel (on page
25
).
WARNING:
Eliminate the risk of electric shock by removing all AC power from the system before
installing or replacing any non-hot-plug hardware option. Disconnect all power cords to
completely remove power from the server.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
IMPORTANT:
You have to remove the primary PCIe riser cage if a full-length expansion board is
installed.
5.
If a full-length expansion board is installed in slot 1, release the full-length expansion board retainer,
and then remove the primary PCIe riser cage.
Summary of Contents for ProLiant DL385p
Page 65: ...Hardware options installation 65 o 8 or 16 drive SFF o 8 drive LFF ...
Page 91: ...Cabling 91 LFF hard drive cabling Optical drive cabling ...
Page 92: ...Cabling 92 FBWC cabling 8 or 16 drive SFF 8 drive LFF ...
Page 132: ...Support and other resources 132 ...
Page 133: ...Support and other resources 133 ...