Hardware options installation 65
Populated DIMM speed — Intel Xeon E5-2600 v4 processor installed
Type
Rank
Capacity
(GB)
1 DIMM per
channel (MT/s)
2 DIMMs per
channel (MT/s)
3 DIMMs per
channel (MT/s)
RDIMM
Single
8 or 16
2400
2133
1866
NVDIMM-N
(RDIMM)
Single
8
2133
1866
1600
RDIMM
Dual
16 or 32
2400
2400
1866
LRDIMM
Dual
32
2400
2400
2400
LRDIMM
Quad
64
2400
2400
2400
LRDIMM
Octal
128
2400
2400
2400
The operating memory speed is a function of the rated DIMM speed, DIMMs installed per channel,
processor model, and the speed selected in the BIOS/Platform Configuration (RBSU) of the UEFI System
Utilities.
Depending on the processor model, the number of DIMMs installed, and whether LRDIMMs or RDIMMs
are installed, the memory clock speed can be reduced to 1866 MT/s.
Maximum memory capacity
The maximum memory capacity is a function of the DIMM capacity, number of installed DIMMs, number
of NVDIMMs, memory type, and number of installed processors.
Maximum memory capacity — Intel Xeon E5-2600 v3 processor installed
DIMM type DIMM rank Capacity (GB) One processor (GB) Two processors (GB)
RDIMM
Single
4
48
96
RDIMM
Single
8
96
192
RDIMM
Dual
8
96
192
RDIMM
Dual
16
192
384
RDIMM
Dual
32
384
768
LRDIMM
Dual
16
192
384
LRDIMM
Dual
32
384
768
LRDIMM
Quad
64
768
1536
Maximum memory capacity — Intel Xeon E5-2600 v4 processor installed
DIMM type DIMM rank Capacity (GB) One processor (GB) Two processors (GB)
RDIMM
Single
8
96
192
RDIMM
Single
16
192
384
RDIMM
Dual
16
192
384
RDIMM
Dual
32
384
768
LRDIMM
Dual
32
384
768
LRDIMM
Quad
64
768
1536
LRDIMM
Octal
128
1536
3072
For the latest memory configuration information, see the QuickSpecs on the Hewlett Packard Enterprise
website (
SmartMemory
SmartMemory authenticates and unlocks certain features available only on Qualified memory and verifies
whether installed memory has passed Hewlett Packard Enterprise qualification and test processes.
Summary of Contents for ProLiant DL380 Gen9
Page 34: ...Operations 34 5 Install the air baffle ...
Page 90: ...Hardware options installation 90 o Connected to a PCI expansion board ...
Page 102: ...Hardware options installation 102 o Connected to a PCI expansion board ...
Page 104: ...Hardware options installation 104 o Secondary riser cage o PCI blank ...
Page 128: ...Hardware options installation 128 o 24SFF drive backplanes Group C SAS cables ...
Page 148: ...Cabling 148 o Connect to a PCI expansion board ...
Page 149: ...Cabling 149 o Connect to an HPE 12G SAS Expander Card Bay 2 installation ...
Page 154: ...Cabling 154 Drive bay 1 is empty Connect using the NVMe power cable 776392 001 ...
Page 171: ...Cabling 171 x4 SATA connector Connect the 2 SFF drive bay power cable ...
Page 173: ...Cabling 173 Secondary PCI riser cage ...
Page 204: ...Support and other resources 204 ...
Page 205: ...Support and other resources 205 ...