Removal and replacement procedures 49
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power
supply or power supply blank to cool before touching it.
To replace the blank, slide the blank into the bay until it locks into place.
Hot-plug fan
WARNING: To reduce the risk of electric shock, personal injury, and damage to the
equipment:
•
Do not attempt to service any parts of the equipment other than those specified in the
following procedure. Any other activities may require that you shut down the server
and remove the power cord.
•
Installation and maintenance of this product must be performed by individuals who
are knowledgeable about the procedures, precautions and hazards associated with
the product.
You must observe the following requirements when installing redundant hot-plug fans:
•
To ensure optimum cooling, populate the primary fan locations, 2, 4, 5, 6, and 7, before populating
the redundant locations ("
Identifying hot-plug fans
" on page
90
).
•
If a primary fan fails, replace the non-functioning fan before installing fans in redundant locations
("
Identifying hot-plug fans
" on page
90
).
To remove the component:
1.
Extend or remove the server from the rack ("
Extend the server from the rack
" on page
19
, "
Remove
the server from the rack
" on page
20
).
2.
Remove the access panel ("
Access panel
" on page
22
).
3.
If the server is operating with less than seven functional fans, power down the server (on page
20
),
then continue with the next step.