148
Step Command
Remarks
5.
Set the IGMP last-member
query interval.
igmp-snooping
last-member-query-interval
interval
1 second by default.
Configuring source IP addresses for IGMP queries
After an IGMP snooping-enabled router receives an IGMP query whose source IP address is 0.0.0.0 on
a port, it does not enlist that port as a dynamic router port. This might prevent multicast forwarding entries
from being correctly created at the data link layer and eventually cause multicast traffic forwarding to fail.
To avoid this problem, when a Layer 2 switch acts as the IGMP snooping querier, HP recommends you
to configure a non-all-zero IP address as the source IP address of IGMP queries.
Changing the source address of IGMP queries might affect the IGMP querier election within the subnet.
To configure source IP addresses for IGMP queries:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter VLAN view.
vlan
vlan-id
N/A
3.
Configure the source IP
address for IGMP general
queries.
igmp-snooping general-query source-ip
{
ip-address
|
current-interface
}
0.0.0.0 by default.
4.
Configure the source IP
address for IGMP
group-specific queries.
igmp-snooping special-query source-ip
{
ip-address
|
current-interface
}
0.0.0.0 by default.
Configuring IGMP snooping proxying
This section describes how to configure IGMP snooping proxying.
Configuration prerequisites
Before you configure IGMP snooping proxying in a VLAN, complete the following tasks:
•
Enable IGMP snooping in the VLAN.
•
Determine the source IP address for the IGMP reports sent by the proxy.
•
Determine the source IP address for the IGMP leave messages sent by the proxy.
Enabling IGMP snooping proxying
The IGMP snooping proxying function works on a per-VLAN basis. After you enable the function in a
VLAN, the device works as the IGMP snooping proxy for the downstream hosts and upstream router in
the VLAN.
To enable IGMP snooping proxying in a VLAN:
Step Command
Remarks
1.
Enter system view.
system-view
N/A