![HP ML115 - ProLiant - G5 User Manual Download Page 51](http://html.mh-extra.com/html/hp/ml115-proliant-g5/ml115-proliant-g5_user-manual_164495051.webp)
Server software and configuration utilities 51
1.
Power up the server. If the server is already powered, save all data, exit all open applications, and
restart.
NOTE:
Enabling the RAID option in BIOS Setup Utility is only necessary for installation of the
RAID driver. If this option is not enabled, the OS loads the standard ATA driver from the OS
media.
2.
During POST, press the
F10
key to launch BIOS Setup Utility. If you fail to press
F10
before POST, you
will need to restart the server.
3.
In the Advanced menu screen, select
IDE Configuration
.
4.
Select the
ATA/IDE Configuration>Enhanced
field.
5.
Set the
Configure SATA
field to
Enabled
.
6.
Press
F10,
then select
Yes
to save the changes and close BIOS Setup Utility. The server automatically
reboots.
7.
Create a RAID volume ("
Creating a RAID volume
" on page
52
).
ProLiant ML110 Generation 2, ML110 Generation 4, ML110 Generation 5, ML150
Generation 2, and ML150 Generation 3 Servers
CAUTION:
Back up any data stored on the hard drives before proceeding. The configuration
process erases all data on the hard drives.
1.
Power up the server. If the server is already powered, save all data, exit all open applications, and
restart.
NOTE:
Enabling the RAID option in BIOS Setup Utility is only necessary for installation of the
RAID driver. If this option is not enabled, the OS loads the standard ATA driver from the OS
media.
2.
During POST, press the
F10
key to launch BIOS Setup Utility. If you fail to press
F10
before POST, you
will need to restart the server.
3.
In the Advanced menu screen, select
Advanced Chipset Control
.
4.
Set the
Serial ATA
field to
Enabled
.
5.
Select the
SATA Controller Mode Option>Enhanced
field.
6.
Set the
SATA RAID Enable
field to
Enabled
.
7.
Press
F10,
then select
Yes
to save the changes and close BIOS Setup Utility. The server automatically
reboots.
8.
Create a RAID volume ("
Creating a RAID volume
" on page
52
).
ProLiant ML150 Generation 5 Servers
CAUTION:
Back up any data stored on the hard drives before proceeding. The configuration
process erases all data on the hard drives.
1.
Power up the server. If the server is already powered, save all data, exit all open applications, and
restart.
NOTE:
Enabling the RAID option in BIOS Setup Utility is only necessary for installation of the
RAID driver. If this option is not enabled, the OS loads the standard ATA driver from the OS
media.