12
6.
Set the “BMC LAN Configuration” to “DHCP”
7.
Press the F10 key to save and exit RBSU
To configure a static IP address, use the RBSU with the following procedure to disable DHCP and
configure the IP address and the subnet mask:
1.
Power on the server by pressing the Power on/Off button on the front panel
2.
When POST prompts the message “press F10 for Rom-based setup Utility”, press the F10 key, the
main screen of the BIOS Setup Utility appears
3.
Press the right arrow (
→
) key to na vig a te to the
“Advanced” menu.
4.
Press the down arrow (
↓
) key to scroll to
“IPMI Configuration”. Press the Enter key.
5.
Press the down arrow (
↓
) key to scroll the
“Set LAN Configuration” menu. Press the Enter key.
6.
On “BMC LAN Configuration”, select “static”
7.
Press the down arrow (
↓
) key to scroll dow n a nd enter a va lid IP a ddress, subnet ma sk, a nd
gateway address (press period (.) key to move between address fields).
Summary of Contents for MicroServe
Page 1: ...HP MicroServer Remote Access Card User Manual Part Number 664489 002 February 2013 Edition 2 ...
Page 16: ...16 4 Then it will login the CLP console ...
Page 18: ...18 3 Then click Upload button then click OK to upload firmware 4 Update is running ...
Page 19: ...19 5 Update is finished 6 Connect the Web UI again to check the current BMC firmware version ...
Page 21: ...21 4 Update is running 5 Update is finished ...
Page 25: ...25 3 Update is running 4 Connect the Web UI to check the current BMC firmware version ...
Page 57: ...57 Enter admin1 system1 memory1 and you can get memory info with show verb ...
Page 59: ...59 ...
Page 60: ...60 ...