6.
Secure the slides to the server.
7.
Install the cable management arm.
a.
Attach screws
(B)
to the left rear column.
b.
Slip the cable management arm over the screws
(B)
and tighten.
c.
Extend the cable management arm to the left rear
side of the product.
d.
Attach the cable management arm to the studs, and
secure it with nuts
(E).
8.
Install the bezel front.
9.
Install the interlock device.
NOTE:
If the rack is bolted to the floor or is used in
a rack configuration with at least four bayed racks,
then the interlock device is not necessary. If two
products are installed and the rack depth is no more
than 717.55 mm (28.25 in), the interlock device
can be installed so that you can remove one product
at a time.
NOTE:
The products must be racked adjacent to
each other to use the interlock device.
NOTE:
If four products are installed in the rack and
interlock devices are used, then two interlock devices
are needed, with one device connected to the
bottom two products, and the other device
connected to the top two products.