![HP Integrity Superdome X Service Manual Download Page 81](http://html.mh-extra.com/html/hp/integrity-superdome-x/integrity-superdome-x_service-manual_164489081.webp)
values.
Recommended Action 1 :
Reboot the system which attempts to reinitialize the
interface.
Probable Cause 2 :
Reboot of the system fails to restore SFW communication to Gromit iLO via
the SMIF over CHIF interface
Recommended Action 2 :
Power off the system. Reset the offending Gromit iLO(s) in the system
with one of the following:
1) destroy and recreate the partition 2) reset the blade using 'reset
blade X' then confirm 'yes'
3) reset iLO and reboot the
system.
Replaceable Unit(s) :
Part Manufacturer : Not Applicable
Spare Part No. : Not Applicable
Part Serial No. : Not Applicable
Part Location : Not Applicable
Additional Info : Not Applicable
Additional Data :
Severity : Degraded/Warning
Alert Type : Communications Alert
Event Category : Support Firmware
Event Subcategory : Other
Probable Cause : Communications Protocol Error
Other Event Subcategory : Gromit iLO Configuration Error
Event Threshold : 1
Event Time Window : 0 (minutes)
Actual Event Threshold : 1
Actual Event Time Window : 0 (minutes)
Record ID : 0x0
Record Type : E1
Reporting Entity : 0x0100ff03ff000017 enclosure1/blade3/
cpusocket0/cpucore0
Alert Level : 0x3
Data Type : 0x16
Data Payload : 0x1
Extended Reporting Entity ID : 0x2
Reporting Entity ID : 0x1
IPMI Event ID : 0x2b05
OEM System Model : NA
Original Product Number : AH337A
Current Product Number : AT147A
OEM Serial Number : NA
Version Info :
Complex FW Version : 7.6.0
Provider Version : 5.111
Error Log Data :
Error Log Bundle : 400000000001e86c
See the
HPE Integrity Superdome X and Superdome 2 Onboard Administrator Command Line Interface
Guide
for the correct and detailed command syntax. The HR Viewer can also provide help in visualizing
component issues.
Troubleshooting
81