Chapter 1
Overview
Utilities Subsystem
31
- Supports USB for keyboard and mouse at boot
- Supports VGA during boot
- Enables global shared memory (GSM)
- Supports PCI 2.3, PCI-X 1.0, and PCI-X 2.0
UGUY
Every cabinet contains one UGUY. Refer to Figure 1-2. The UGUY plugs into the HUCB. It is not hot
swappable. Its MP microprocessor controls power monitor functions, executing the Power Monitor 3 (PM3)
firmware and the cabinet-level utility (CLU) firmware.
The UGUY consists of two main components:
- CLU
- PM3
Figure 1-2
UGUY
CLU Functionality
The CLU is responsible for collecting and reporting the configuration information for itself, main backplane,
I/O backplanes, and the SUB/HUB. Each of these boards is furnished with a configuration EEPROM
containing FRU IDs, revision information, and, for the main backplane and I/O backplanes, maximum power
requirements for that entity in its fully configured, fully loaded state. The power requirement information is
sent to the PM3 automatically when HKP is applied or when a new entity is plugged in. The configuration
information is sent to the SUB in response to a
get_config
command.
The CLU gathers the following information over its five I2C buses:
- Board revision information is contained in the board's configuration EEPROM for the UGUY board (UGUY),
the SBCH board (SBCH), the main backplane, the main backplane power boards (HBPB), the I/O backplane
(HIOB), and the I/O backplane power boards (IOPB).
- Power requirements from the configuration EEPROM for the main backplane (HLSB or HRSB), the I/O
backplanes (HIOB). This information is sent to the PM3 processor (via USB) so that it can calculate cabinet
power requirements.
- Power control and status interface. Another function of the UGUY is to use the power_ good signals to drive
power on
- Reset control which includes a reset for each I/O backplane, a main backplane cabinet reset, TRST - JTAG
reset for all JTAG scan chains in entire cabinet, a system clock control margin control
Summary of Contents for Integrity Superdome sx2000
Page 8: ...Contents 8 ...
Page 10: ...Tables 10 ...
Page 14: ...Figures 14 ...
Page 53: ...Chapter 1 Overview New Server Cabling 53 Figure 1 11 Backplane Cables ...
Page 169: ...Appendix A 169 A sx2000 LEDs ...
Page 174: ...Appendix A sx2000 LEDs 174 ...
Page 187: ...Appendix B Management Processor Commands MP Command HE 187 Example B 11 HE Command ...
Page 199: ...Appendix B Management Processor Commands MP Command PS 199 Example B 20 PS Command ...
Page 212: ...Appendix B Management Processor Commands MP Command XD 212 ...
Page 230: ...Appendix D Templates Templates 230 Figure D 2 SD16 and SD32 Space Requirements ...
Page 233: ...Appendix D Templates Templates 233 Figure D 4 Computer Floor Template ...
Page 234: ...Appendix D Templates Templates 234 Figure D 5 Computer Floor Template ...
Page 235: ...Appendix D Templates Templates 235 Figure D 6 Computer Floor Template ...
Page 236: ...Appendix D Templates Templates 236 Figure D 7 Computer Floor Template ...
Page 237: ...Appendix D Templates Templates 237 Figure D 8 Computer Floor Template ...
Page 244: ...Appendix D Templates Templates 244 ...
Page 247: ...Index 247 W wiring check 101 wrist strap usage 76 ...