![HP HPE ProLiant DL180 Gen10 Maintenance And Service Manual Download Page 42](http://html.mh-extra.com/html/hp/hpe-proliant-dl180-gen10/hpe-proliant-dl180-gen10_maintenance-and-service-manual_164421042.webp)
To replace the component, reverse the removal procedure.
Removing and replacing an NVMe drive
An NVMe SSD is a PCIe BUS device. Devices attached to a PCIe bus cannot be removed without
allowing the device and the bus to complete and cease signal/traffic flow.
Procedure
1.
Back up all server data on the drive.
2. Determine the status of the drive from the drive LED definitions
3.
Remove the drive.
a.
Push the Power button.
The Do Not Remove button illuminates and flashes.
b.
Wait until the flashing stops and the Do Not Remove button is no longer illuminated.
c.
Push the Do Not Remove button and then remove the drive.
To replace the component, reverse the removal procedure.
42
Removal and replacement procedures
Summary of Contents for HPE ProLiant DL180 Gen10
Page 14: ...14 Customer self repair ...
Page 15: ...Customer self repair 15 ...
Page 16: ...16 Customer self repair ...
Page 17: ...Customer self repair 17 ...
Page 56: ... Secondary riser cage Slot 4 Slot 5 or 6 56 Removal and replacement procedures ...
Page 63: ... Secondary riser cage Slot 4 Slot 5 or 6 Removal and replacement procedures 63 ...
Page 124: ... 24 bay SFF hot plug drive model Fan bay numbering 124 Component identification ...
Page 130: ...Box 2 to type a controller Box 2 to type p controller 130 Cabling ...
Page 131: ...Box 3 to system board Box 3 to type a controller Cabling 131 ...
Page 132: ...Box 3 to type p controller 8 bay SFF power cable default 132 Cabling ...
Page 137: ...Mini SAS cable to SAS expander Cabling 137 ...
Page 139: ... M 2 SSD enablement board installed in secondary riser Cabling 139 ...
Page 144: ...Cable routing Serial port Cable routing iLO Service Port SFF LFF 144 Cabling ...
Page 146: ... Secondary riser cage Slot 4 Slot 5 or 6 146 Cabling ...