Routing table size
8000 entries
Environment
Operating temperature
32°F to 122°F (0°C to 50°C)
Operating relative
humidity
15% to 95% @ 104°F (40°C), noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
15% to 90% @ 149°F (65°C), noncondensing
Altitude
up to 10,000 ft. (3 km)
Acoustic
Power: 0 dB, Pressure: 0 dB No Fan
Electrical characteristics Maximum heat
dissipation
142 BTU/hr (149.81 kJ/hr)
Voltage
100-127/200-240 VAC
Current
0.8/0.4 A
Maximum power rating
41 W
Frequency
50/60 Hz
Notes
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all modules
populated.
Safety
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated
IEC 61000-4-3; 3V/m
EFT/Burst
IEC 61000-4-4; 1.0 kV (power line), 0.5kV (signal
line)
Surge
IEC 61000-4-5; 1 kV/2 kV AC
Conducted
IEC 61000-4-6; 3V
Power frequency
magnetic field
IEC 61000-4-8; 1A/m,50 or 60 Hz
Voltage dips and
interruptions
IEC 61000-4-11; >95% reduction, 0.5 period; 30%
reduction, 25 periods
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
Management
HP PCM+; HP PCM (included); command-line interface; Web browser;
configuration menu; out-of-band management (serial RS-232C)
Notes
When using mini-GBICs with this product, mini-GBICs with revision "B" or later
(product ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (U4683E)
QuickSpecs
HP 2610 Switch Series
Technical Specifications
DA - 13032 Worldwide — Version 18 — November 11, 2013