Determine installation positions for the mounting brackets and grounding cable as required.
Figure 6 Mounting brackets and grounding cable installation positions on the switch
(1) Mounting bracket installation position near the power supply side
(2) Primary grounding point
(3) Auxiliary grounding point
(4) Mounting bracket installation position near the port side
Attaching the mounting brackets and chassis rails to the
chassis
1.
Place the wide flange of the mounting bracket against the chassis side panel. Align the
mounting bracket installation holes with the screw holes in the chassis. Use M4 screws
(provided) to attach the mounting bracket to the chassis.
To install the mounting brackets at the power supply-side mounting position, see
Figure 7
.
To install the mounting brackets at the port-side mounting position, see
Figure 8
.
2.
Determine the chassis rail installation position:
If the mounting brackets are installed at the power supply-side mounting position, install the
chassis rails near the port side.
If the mounting brackets are installed at the network port-side mounting position, install the
chassis rails near the power supply side.
3.
Place the chassis rail against the chassis side panel. Align the chassis rail installation holes with
the screw holes. Use M4 screws (provided) to attach the chassis rail to the chassis. See
Figure
7
and
Figure 8
.