81
NOTE:
Up to eight power supplies can be installed on a 12910 AC switch.
Card LEDs
The MPU has the LEDs numbered the same as card slots to indicate the status of the active MPU, standby
MPU, LPUs, and switching fabric modules in the slots.
On each 12910 AC switch:
•
The slot numbers of LPUs are marked above the slots on the front panel.
•
The slot numbers of MPUs and switching fabric modules are marked to the right of the slots on the
rear panel.
Table 43
Card LED description
RUN ALM
Description
Flashing (1
Hz)
Off
The card is operating correctly.
Flashing (8
Hz)
Steady on
The card is loading software.
(If the RUN LED keeps flashing and the ALM LED keeps steady on, the software
version of the switch does not match that of the card.)
Flashing (1
Hz)
Flashing
(0.5 Hz)
The temperature of the card is higher than the alarm threshold.
Steady on
Steady on
The card is starting up or the card is faulty.
Off
Off
The card is not in position.
NOTE:
It is normal that the ALM LED for an LPU lights for a period of time at the initial phase of the system startup.
MPU active/standby status LED
The MPU has one ACTIVE LED to indicate the active or standby status of the MPU.
Table 44
MPU ACTIVE LED description
LED status
Description
On
The MPU is active.
Off
•
The MPU is in standby status.
•
The MPU is faulty. Examine the card LED for an MPU problem.
LPU LEDs
The HP FlexFabric 12900 switches support SFP+ ports and QSFP+ ports.
SFP+ port LED
The LPUs provide one SFP+ port LED for each SFP+ port to indicate the link status and data
receiving/forwarding status of the SFP+ ports.