HP Array Configuration Utility 44
3.
Click
Enable HP SmartCache
.
4.
Select a solid state drive type.
5.
Select one or more physical drives from the list of available drives.
6.
Click
Save
.
Some features may not be available with HP SmartCache enabled.
7.
With the SmartCache selected in the left panel, click
Create SmartCache for Logical Drive
.
8.
Select the logical drive to cache.
9.
Select the size of the cache. HP recommends 10% of the drive size, and it must be a minimum of 1 GiB.
10.
Click
Save
.
The SmartCache is created for the Logical Drive.
Working with mirrored arrays
Among the advanced tasks possible with the ACU GUI, you can split a mirrored array and then recombine
it. This process entails breaking a RAID 1 or RAID 1+0 mirror into two identical new arrays consisting of RAID
0 logical drives.
Support for these procedures requires the following:
•
The ACU GUI must be run in offline mode.
•
Select controller models must have a valid SAAP license ("
About SAAP
" on page
8
).
•
Mirrored arrays being split can have RAID 1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM)
configurations. Arrays with other RAID configurations cannot be split.
Several reasons exist for splitting and recombining a mirrored array. For more information, see the "
RAID
1(+0): breaking mirrors and rebuilding drives
" how-to white paper on the HP website
(
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00378986/c00378986.pdf
).