NOTE:
To update SAS controller firmware online, you must be running
version 11.31.0909 or higher of the
sasd
driver. Online SAS controller firmware
updates are not supported on systems running HP-UX 11i v2.
If you do not specify the
-f
option with this command,
sasmgr
displays a
warning message before continuing. Otherwise, it suppresses the warning
message and executes the command.
enable
Enables the controller and brings it back online. This command causes the
driver to initialize the controller. Use this command to bring the controller
back online after using the
disable
command.
get_info
When the
get_info
command is run without qualifiers, it returns information
about the controller represented by
device_file
. The following qualifiers
may be specified with the
get_info
command:
•
lun
- Shows hardware path and SAS address information for a specific
LUN or all LUNs. If the
-N
option and the
-q lun=all
qualifier are
specified with this command, then it displays persistent device file
information.
•
lun_locate
- Shows LUN location information for the LUN specified
with the LUN qualifier. If the
-N
option and the
-q lun=all
qualifier
are specified with this command, then it displays persistent device file
information with the LUN location information.
•
pci_id
- Shows PCI ID information for the controller.
•
phy
- Shows information about all PHYs or a specific PHY.
•
phy_in_port
- Shows information about a port to which the specified
PHY belongs or provides information about all ports.
•
raid
- Shows RAID configuration information for the controller. If the
-N
option is specified with this command, then it displays persistent
device file information.
•
reg
- Displays the contents of a specific PCI config space or MMIO register
or all PCI config spaces or MMIO registers. PCI config space or MMIO
register type is specified with the reg_type qualifier. If
reg_type
is not
specified, then the command assumes a default register type of MMIO.
•
smp_addr
- Shows the SMP initiator SAS address to send SMP requests.
•
target
- Shows information about a specific target or all targets.
•
vpd
- Shows vital product data information for the controller.
get_stat
When the
get_stat
command is run without qualifiers, it shows statistics
about the controller represented by
device_file
. The following qualifiers
may be specified with the
get_stat
command:
•
phy
- Shows statistics for all PHYs or a specific PHY.
•
phy_in_port
- Shows statistics for a port to which the specified PHY
belongs to or provides statistics for all ports.
•
target
- Shows statistics for a specific target or all targets.
replace_tgt
The following qualifiers must be specified with the
replace_tgt
command:
•
old_dev
•
new_tgt_hwpath
Allows the
lun_dsf
specified with
old_dev
to be associated with a new SAS
target, which is specified with the
new_tgt_hwpath
qualifier. The
lun_dsf
must be the legacy device file and the
new_hw_path
must be the legacy
hardware path.
56