Operating the Core Switch 2/64
120
Core Switch 2/64 V4.1 Installation Guide
psShow
This command displays the current status of the power supplies, as shown in the
following example.
sw0_155:admin> psShow
power supply #1 is OK
power supply #2 is OK
power supply #3 is OK
power supply #4 is OK
fanShow
This command displays status and RPM of the blower assemblies, as shown in the
following example.
sw0_155:admin> fanshow
Fan #1 is OK, speed is 2576 RPM
Fan #2 is OK, speed is 2481 RPM
Fan #3 is OK, speed is 2481 RPM _
errShow
This command shows the switch error log that lists the status of marginal/failed
components. The following example shows that the Switch 0 blower assembly has
failed.
sw0_155:admin> errshow
Error 15
--------
0x2e3 (fabos): Dec 29 15:57:34
Switch: 0, Error FW-BELOW1, 3, envFan001 (Env Fan 1) is below
low boundary. current value : 0 RPM. (faulty)