![HP A6616 Installation Manual Download Page 25](http://html.mh-extra.com/html/hp/a6616/a6616_installation-manual_163041025.webp)
(4) 1000 Mbps optical Ethernet interface LED (SFP1)
(5) Run LED (RUN)
Table 1-18
Description of FIP-100 LEDs
LED
Status
Meaning
RUN (green)
Off
No power input is available or the FIP-100 has failed.
Slow blinking (1 Hz)
The FIP-100 is working normally.
Fast blinking (8 Hz)
Application program is being loaded (in this case, never power
off the device or hot-swap the FIP-100; otherwise, the FIP-100
may be damaged) or the FIP-100 is not working.
SFP0 and SFP1
(yellow/green)
Off
No optical link is present.
Solid green
An optical link is present.
Blinking green
Data is being sent or received at a rate of 1000 Mbps.
Solid yellow
The optical transceiver has failed in POST.
GE0 and GE1
(yellow/green)
Off
No link is present.
Solid green
A 1000 Mbps link is present.
Blinking green
Data is being received or transmitted at a rate of 1000 Mbps.
Solid yellow
A 10/100 Mbps link is present.
Blinking yellow
Data is being received or transmitted at a rate of 10/100 Mbps.
Slots
FIP-100s can be inserted into Slot 0 through Slot 3, and Slot 6 through Slot 9 on the A6616. The
slots on a FIP-100 are numbered 1 to 4 from the bottom up and from right to left, as shown in
Figure 1-16
.
Figure 1-16
Interface module slots on the FIP-100
The numbers 1 through 4 in
Figure 1-16
represent Slot 1 through Slot 4 respectively.
Maximum interface modules provided by FIP-100s in full configuration
Table 1-19
Maximum interface modules provided by FIP-100s in full configuration
Interface module
One RPE-X1
Two RPE-X1s
One RSE-X1
Two RSE-X1s
FIP-100
8
8
Not supported
Not supported
MIMs
32
32
—
—
HIMs
Not supported
Not supported
Not supported
Not supported