System Specifications
Physical and Environmental Specifications
Chapter 2
53
Physical and Environmental Specifications
Table 2-7 provides temperature and airflow information for minimum, typical, and maximum configurations
for the HP 9000 rp4410 and rp4440servers. It also lists the server and rack weights and dimensions.
Table 2-7
Physical and Environmental Specifications
Condition
Weight
Overall Server
(W x D x H)
Typical
Heat
Release
Airflow, Nominal
Airflow, at
Maximum
Ambient
degrees C
a
a.
Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters.
180-264
VAC
Server
Alone
Rack
Pede-
stal
Rack
Pede-
stal
Min.
Config.
410 Watts
175
CFM
297
m
3
/hr
250
CFM
425
m
3
/hr
88 lbs
(40 kg)
100 lbs
(45.4 kg)
115 lbs
(53 kg)
W: 19 in
(48.2 cm)
D: 27.2 in
(69.0 cm)
H: 6.8 in
(17.3 cm)
W: 10.3 in
(26.1 cm)
D: 27.4 in
(69.5 cm)
H: 20.9 in
(53.0 cm)
Max.
Config.
1368 Watts
Typical
Config.
1065 Watts
ASHRAE
Class 1
Airflow cooling scheme (front to
rear)
Min./
Config.
One CPU, one power supply, 1 GB DIMM, zero
DVD, one HDD, zero PCI cards, one core I/O.
Max.
Config.
Four CPUs, two power supplies, 128 GB DIMM,
one DVD, two HDD, six PCI cards, two core I/O.
Typical
Config.
Two CPUs, two power supplies, 16 GM DIMM,
one DVD, two HDD, two PCI cards, one core I/O.