![HP 850F Operating Manual Download Page 5](http://html.mh-extra.com/html/hp/850f/850f_operating-manual_161499005.webp)
5
1
Transformer Jaw: designed to pick up the AC and DC
current flowing through the conductor. It could transfer
current to voltage. The tested conductor must vertically
go through the Jaw center
2
Hand Guards: to protect user’s hand from
touching the dangerous area.
3
LIGHT button (auto display backlight button)
4
MIN/
▼
button
5
LOAD button (recall data)
6
LCD Display
7
A Input Terminal (First phase measurement)
8
B Input Terminal
(Second phase measurement)
9
COM Input Terminal
10
C Input Terminal (Third phase measurement)
11
CLEAR button (maximum and minimum)
12
SELECT button (press to select alternate
function and sum of Watts measurement)
13
button (Sum)
14
SAVE button (data store button)
15
Max
/▲
button
16
HOLD button
17
Rotary Switch
18
USB
19
The distributing line device will avoid the dangerous when
distributing electrical wire with hands
20
Leads Cramp in the Clamp easy for fixed one Lead when
you need test two separation vertices