![HP 850F Operating Manual Download Page 32](http://html.mh-extra.com/html/hp/850f/850f_operating-manual_161499032.webp)
32
40 ~ 50 ( 45%R.H)
Storage:-10 ~ +60 ( 85%R.H)
●
Safety/ Compliances: IEC 61010 CAT.III 600V,
CAT.IV 300V overvoltage and double insulation standard, pollution degree 2
●
Certification:
Accurate Specifications
Accuracy :±(a% r b digits),guarantee for 1 year.
Operating temperature:23
℃
±5
℃
Operating humidity:45
~
75%R.H
A. AC Voltage (True RMS)
B. Frequency
Range
Resolution
Accuracy
20Hz
~
100Hz
1Hz
± (0.5%+5)
Min Input Voltage
:
10V
C. AC Current (True RMS)
Range
Resolution
Accuracy
Allowable Maximum overload
protection current
40A
0.1A
± (2.5%+15)
1000A RMS
400A
1000A
400-800
1A
± (2.5%+15)
Range Resolution Accuracy
Allowable Maximum overload
protection voltage
Input
Impedance
15V
0.1V
± (1.2%+5)
600 RMS
10 MΩ
100V
300V
600V