HP 85027A/B/C Performance Tests
*Approxin-~ateuncertainity excluding effect of any adapter used.
DYNAMIC POWER ACCURACY (AC and DC)
Specifications
The dynamic power accuracy specifications for the bridge in AC mode are
incorporated in Table 4-3, Dynamic Power Accuracy, which follows.
Description
Using the setup illustrated
HP 85027.
Equipment
in Figure 4-5 to measure the dynamic power accuracy of the
HP 85027A
HP 85027B
HP85027C
Sweep Oscillator
RF Plug-in
Scalar network analyzer
Short/open
Adapter(s)
Step attenuator
HP 835011
HP 83592A
HP 8757A
85021-60001
1250- 1475
8495B opt 001
HP 835011
HP 83595A
HP 8757A
85037-60001
85027-60002
8495D opt 004
HP 835011
HP 83592A
HP 8757A
1 1512A/85033-60001
1250-1475
8495B opt 001
~r~1
I~I
-
.
ONLY REQUIRED
IF
NP
83508 HAS
SERIAL PREFIX
2436 OR BELOW.
BRIDGE
Figure 4-5. Dynamic Power A ccuracv Performance Test Setup