3-9
Quality
Climatic and Dynamic Environmental Ruggedness
Temperature, Humidity, and Altitude Test Suite
Table 3-16 and Table 3-17 summarize the temperature tests suite.
Table 3-18 and Table 3-19 summarize the humidity tests suite.
Table 3-20 and Table 3-21 summarize the altitude test suite.
Table 3-16
Temperature Tests While Non-Operations
Standard
Level
HP class B1 (IEC 654 Part 1 class C3 compatible)
-40 Deg C to 71 Deg C
(-40 Deg F to 159.8
Deg F)
Table 3-17
Temperature Tests During Operation
Standard
Level
HP class B1
(IEC 654-1 class Bx compatible)
0 Deg C to 55 Deg C (41 Deg F to 131 Deg F)
Temperature slew rate
(exceeds IEC 654-1)
10 Deg C/minute (50 Deg F/minute)
Table 3-18
Humidity Tests While Non-Operational
Standard
Level
HP class B
90% relative humidity at 65 Deg C
Table 3-19
Humidity Tests During Operation
Standard
Level
Condensation
<5 minutes recovery
HP class B
15% to 95% relative humidity at 40 Deg C
Table 3-20
Altitude Tests While Non-Operating
Standard
Level
HP Standard 761 (class B) (exceeds IEC 654-1)
4.6 Km (15 Kft)
Table 3-21
Altitude Tests During Operation
Standard
Level
HP Standard 761 (class B) (exceeds IEC 654-1)
4.6 Km (15 Kft)