Chapter 4 Command Reference
:STATus Subsystem
Programming Guide
4-35
4
•
The value of unused bits is zero when queried and is ignored when set.
•
A TRUE bit in the positive transition filter specifies that a positive
(FALSE to TRUE) transition of the corresponding bit in the Operation
Condition Status Register generates the corresponding event in the
Operation Event Status Register.
•
At power-on and STAT:PRES, the positive transition filter is preset
such that each bit is a 1 (TRUE).
•
This value is unaffected by *RST, *CLS, and *SAV/*RCL.
RELATED
FRONT-PANEL
KEYS
None
COMMAND
:STATus:PRESet
This event command presets the enable registers and transition filters
associated with the Operation and Questionable status reporting
structures. The enable registers and negative transition filters are preset
such that each bit is a 0 (FALSE). The positive transition filters are preset
such that each bit is a 1 (TRUE).
Summary of Contents for 53150A Series
Page 1: ... Programming Guide HP 53150A 151A 152A Microwave Frequency Counter ...
Page 2: ......
Page 10: ...Contents x Programming Guide ...
Page 11: ...1 Before You Start ...
Page 20: ...Chapter 1 Before You Start Related Documentation 1 10 Programming Guide 1 ...
Page 21: ...2 Command Summary A Quick Reference ...
Page 41: ...3 Programming Your Counter for Remote Operation ...
Page 101: ...4 Command Reference A Dictionary ...
Page 162: ...Chapter 4 Command Reference Common Commands 4 62 Programming Guide 4 ...
Page 163: ...5 Errors ...
Page 174: ...Chapter 5 Errors Error Types 5 12 Programming Guide 5 ...
Page 184: ......
Page 186: ... Manual Part Number 53150 90002 Printed in U S A NOVEMBER 1997 ...