NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct
sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is
30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum
temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa.
Operating and
Operating and
Operating and
Operating and
Performance
Performance
Performance
Performance
Specifications for
Specifications for
Specifications for
Specifications for
CGESM
CGESM
CGESM
CGESM
Interconnect Switch
Interconnect Switch
Interconnect Switch
Interconnect Switch
Dimensions
Dimensions
Dimensions
Dimensions
Height
10.405 in (26.43 cm)
Width
1.6 in (4.06 cm)
Depth
28 in (71.12 cm)
Weight
Weight
Weight
Weight
11.5 lb/5.2 kg per interconnect switch
Performance
Performance
Performance
Performance
28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum Forwarding
Rate (64 Byte Packets)
9018Bytes Jumbo Frames MTU
Non-blocking architecture. Wire Speed Performance on all ports
Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support
Forwarding Mode
Forwarding Mode
Forwarding Mode
Forwarding Mode
Store and forward
MAC Addresses
MAC Addresses
MAC Addresses
MAC Addresses
8000 MAC/physical address Table Size
Memory
Memory
Memory
Memory
128MB DRAM Memory. 16MB Flash Memory
Compliance
Compliance
Compliance
Compliance
IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full
duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree
Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3
10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE
802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification
RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3
(RFC1493) , CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-
MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB,
CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB,
CISCO-IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION-
MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB,
CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS-
MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE-
RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB,
ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not
supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH-
MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO-
SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per
the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my),
RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB,
SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB,
SNMPv2-MIB, TCP-MIB, UDP-MIB
1000BASE-T ports, 1000BASE-X (SFP), 1000BASE-SX
Network Transfer
Network Transfer
Network Transfer
Network Transfer
Rate
Rate
Rate
Rate
10 Base-T (half-duplex)
10 Mbps
10 Base-T (full-duplex)
20 Mbps
100 Base-TX (half-duplex) 100 Mbps
100 Base-TX (full-duplex)
200 Mbps
1000 Base-TX (half and
full-duplex)
2000 Mbps
1000 Base-SX (full-duplex) 2000 Mbps
Connector
Connector
Connector
Connector
4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9