Safety
Safety
Safety
Safety
UL/CUL Listed Accessory
CE
Power Requirements
Power Requirements
Power Requirements
Power Requirements
-48VDC: 1050 mA, 50 W maximum (per interconnect switch)
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
(non-condensing)
(non-condensing)
(non-condensing)
Operating
20% to 80%
Non-operating
5% to 95%
Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb Temperature
Wet Bulb Temperature
Operating
82.4° F (28° C)
Non-operating
101.7° F (38.7° C)
NOTE:
NOTE:
NOTE:
NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No
direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating
limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a
maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa.
Operating specifications
Operating specifications
Operating specifications
Operating specifications
for McDATA 4Gb SAN
for McDATA 4Gb SAN
for McDATA 4Gb SAN
for McDATA 4Gb SAN
Switch
Switch
Switch
Switch
Fibre Channel ports
Fibre Channel ports
Fibre Channel ports
Fibre Channel ports
2 external ports (ships with two 4Gb SFPs)
Performance
Performance
Performance
Performance
4 GB/sec line speed, full duplex
Certified maximum
Certified maximum
Certified maximum
Certified maximum
24 switches, 7 hops; larger fabrics certified as required
Switch core
Switch core
Switch core
Switch core
Non-blocking
Fabric latency
Fabric latency
Fabric latency
Fabric latency
<2 µ sec. with no contention, cut-through routing
Maximum frame size
Maximum frame size
Maximum frame size
Maximum frame size
2112-byte payload
Classes of service
Classes of service
Classes of service
Classes of service
Class 2, Class 3, Class F (inter-switch frames)
Port types
Port types
Port types
Port types
FL_Port, F_Port, and E_Port; self-discovery based on G_Port or GL_Port
Data traffic types
Data traffic types
Data traffic types
Data traffic types
Fabric switches support unicast, multicast (256 groups), and broadcast
Media types
Media types
Media types
Media types
Small Form-Factor Pluggable (SFP)
Laser
Laser
Laser
Laser
Short-wave up to 500 m (1,640 ft); long-wave up to 10 km (6.2 mi) when
available
Options
Options
Options
Options
SFP media-take out
Supported software
Supported software
Supported software
Supported software
SANtegrity Enhanced Software
Management access
Management access
Management access
Management access
10/100 Ethernet (RJ-45)
Diagnostics
Diagnostics
Diagnostics
Diagnostics
POST and embedded online/offline diagnostics
Dimensions
Dimensions
Dimensions
Dimensions
Height
Height
Height
Height
3.4 in (8.6 cm)
Width
Width
Width
Width
1.5 in (3.8 cm)
Depth
Depth
Depth
Depth
4.75 in (12.1 cm) 7 in (17.9 cm) with handle
Weight
Weight
Weight
Weight
1.94 lbs (.88 kg)
Temperature
Temperature
Temperature
Temperature
Operating
Operating
Operating
Operating
32° to 104° F (0° to 40° C)
QuickSpecs
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
HP BladeSystem p-Class Interconnect Components
Technical Specifications
DA - 12331 Worldwide — Version 4 — September 12, 2007
Page 12