To troubleshoot the MPU:
1.
Verify that the power supply is operating properly. For more information, see "
."
2.
Press the RESET button of the MPU to reset the MPU. After the MPU is reset, verify that the
corresponding RUN LED flashes green.
3.
Verify that the MPU is fully seated. You can unplug the MPU, plug it again, and make sure the MPU
is fully seated.
4.
If the switch has empty MPU slots, plug the MPU into an empty MPU slot, and verify that the MPU
can operate properly.
5.
If the failure still exists, contact the local agents or technical support engineers.
LPU failure
When the LPU is operating properly, the LC LED (callout 3 in
) flashes, and the RUN LED on the
LPU flashes in green.
When the two LEDs are not in the states mentioned above, the LPU has failed.
To troubleshoot the LPU:
1.
Verify that the MPU is operating properly. For more information, see "
2.
Use the
display device
command to verify that the software version is compatible with the LPU in
the current slot. If the software version is incompatible with the LPU, upgrade the software to a
compatible version.
3.
Calculate the overall power consumption, and make sure your power supply can provide enough
power.
4.
Verify that the LPU is fully seated. You can unplug the LPU, plug it again, and make sure the LPU is
fully seated.
5.
If the switch has empty LPU slots, plug the LPU into an empty slot, and verify that the LPU can
operate properly.
6.
If the failure still exists, contact the local agents or technical support engineers.
Switching fabric module failure
Table 30
Switching fabric module LED description
LED Status Description
RUN (red/green)
Flashing green
The switching fabric module is operating properly.
Flashing red
The switching fabric is faulty.
Steady on
The switching fabric is faulty.
Off
The switch fabric module is faulty or absent.
When the switching fabric module is operating properly, the SFC LED (callout 2 in
) flashes
green, and the RUN LED on the switching fabric module flashes green.
When the two LEDs are not in the states mentioned above, the switching fabric module has failed.
To troubleshoot the switching fabric module:
Summary of Contents for 12500 Series
Page 36: ...30 Figure 28 Installing an upper expansion cable management bracket 1 2 3 4 5 6 7 ...
Page 98: ...92 Figure 70 Replacing a card for the 12504 A Card to be removed B Card to be installed ...
Page 128: ...122 Figure 81 Loopback operation on an optical transceiver ...
Page 143: ...137 Figure 96 Example of a device label ...
Page 146: ...140 Cable management examples Figure 100 Network cable management ...