58
NA5
METER
WITH
BARGRAPH
X X X X X X X X XX U
Bargraph colour:
3 colours (R, G, R + G) .....................................
T
7 colours (R, G, B, R+G, R+B, G+B, R+G+B)
...M
Display colour:
without display* ........................................................
0
red
.........................................................R
green ........................................................................
G
blue ..........................................................................
B
Input signal:
universal input (table 6) ...................................................
U
on order** .......................................................................
X
Analogue output signal:
without output ..........................................................................
0
current programmed, 0/4...20 mA ...........................................
1
voltage programmed, 0...10 V ..................................................
2
on order** ..............................................................................
X
Digital output signal:
without output .................................................................................
0
RS-485 digital output ......................................................................
1
Additional outputs:
without output .........................................................................................
0
4 relays outputs
.................................................................4
8 OC outputs
.....................................................................8
on order**
.......................................................................X
Supply:
95...253 V a.c./d.c. .........................................................................................
1
20... 40 V a.c./d.c. ..........................................................................................
2
on order** .....................................................................................................
X
Kind of terminals:
socket - screw plug ................................................................................................
0
on order*** ...........................................................................................................
X
Execution:
standard ........................................................................................................................
00
custom-made** ...........................................................................................................
XX
Version:
standard ................................................................................................................................
U
Table 5
10. ORDERING PROCEDURE
Notes:
*
)
In the meter without displays, one must order the RS-485 digital output execution.
**
)
The manufacturer assigns the execution code.
***
)
Available execution with self-locking sockets.