2.2 Operating Modes
Main Operation Modes
Self-consumption Mode
In the daytime, solar energy is
used to power the loads first,
and surplus energy is stored in
the battery. After the battery has
been fully charged or reaches
its maximum charge power, the
excess solar energy is fed back into
the grid (or limited if necessary).
At night, the battery discharge for
the loads first and once the
battery power is insufficient, the
grid supplies power to the loads.
In this mode, battery cannot be
recharged from grid at night.
00:00
Battery discharging
at night
24:00
Consuming from
grid
PV surplus power selling
Loads
Self consuming (PV power generation)
PV Power
Battery charging
charging
standby
standby
discharging
discharging
Power flow of self-consumption mode