![Hoymiles HYT-10.0HV-EUG1 User Manual Download Page 11](http://html1.mh-extra.com/html/hoymiles/hyt-10-0hv-eug1/hyt-10-0hv-eug1_user-manual_2171468011.webp)
Hybrid Inverter User Manual
© 2022 Hoymiles Power Electronics Inc. All rights reserved.
10
2.3.1 Basic Diagram
• This diagram is an example of application that Neutral connects with PE in
distribution box.
• For countries such as Australia, New Zealand, South Africa, etc., please
follow local wiring regulations!
NOTICE
Model
①
②
③
④
⑤
⑥⑦
HYT-5.0HV-EUG1
25A/600V
DC Breaker
16A/230V
AC Breake
r
20A/230V
AC Breaker
Depends on
Loads
Main
Breaker
30 mA RCD
HYT-6.0HV-EUG1
25A/600V
DC Breaker
16A/230V
AC Breaker
25A/230V
AC Breaker
HYT-8.0HV-EUG1
40A/600V
DC Breake
r
20A/230V
AC Breaker
32A/230V
AC Breaker
HYT-10.0HV-EUG1
40A/600V
DC Breake
r
25A/230V
AC Breaker
32A/230V
AC Breaker
HYT-12.0HV-EUG1
40A/600V
DC Breaker
25A/230V
AC Breaker
32A/230V
AC Breaker
A. Diagram for Australia and New Zealand
Note:
If battery integrates a readily accessible internal DC breaker, no additional
①
DC breaker is required.
⑥⑦
30mA RCD is recommended not mandatory, please comply with local regulation, please comply with local regulation.