![Hoymiles HME-1000T-AU User Manual Download Page 24](http://html1.mh-extra.com/html/hoymiles/hme-1000t-au/hme-1000t-au_user-manual_2171439024.webp)
© 2019 Hoymiles Converter Technology Co., Ltd. All rights reserved.
24
HME-1000T/1200T/1350T/1500T-AU
8.3 Efficiency, Safety and Protection
8.4 Mechanical Data
8.5 Features
*Note: Nominal voltage/frequency range can be changed due to the requirements of local power department
Nominal frequency/range (Hz)
45-55 (under 50Hz @ 220V & 230V)
55-65 (under 60Hz @ 220V & 230V)
Power factor
>0.99 default
0.8 leading……0.8 lagging
Output current harmonic distortion
<3%
Maximum units per branch
5@220V
5@230V
5@240V
4@220V
4@230V
4@240V
3@220V
3@230V
3@240V
3@220V
3@230V
3@240V
Model
HME-1000T-AU
HME-1200T-AU
HME-1350T-AU
HME-1500T-AU
Peak inverter efficiency
96.70%
96.70%
96.70%
96.70%
CEC weighted efficiency
96.50%
96.50%
96.50%
96.50%
Nominal MPPT efficiency
99.80%
99.80%
99.80%
99.80%
Night time power consumption
(mW)
<50
<50
<50
<50
Model
HME-1000T-AU
HME-1200T-AU
HME-1350T-AU
HME-1500T-AU
Ambient temperature range (
℃
)
-40 ~ +65
-40 ~ +65
-40 ~ +65
-40 ~ +65
Storage temperature range (
℃
)
-40 ~ +85
-40 ~ +85
-40 ~ +85
-40 ~ +85
Dimensions (W×H×D mm)
326 x 176 x 33
Weight (kg)
4.0
Enclosure rating
Outdoor-NEMA (IP67)
Cooling
Natural convection – No fans
Altitude (m)
<2000
Model
HME-1000T-AU
HME-1200T-AU
HME-1350T-AU
HME-1500T-AU
Communication
2.4GHz Proprietary RF(Nordic)
Monitoring
Hoymiles Monitoring System
(Hoymiles DTU is required)
Warranty
12 years standard, 25 years optional
Compliance
VDE-AR-N 4105:2018, EN50549-1:2019, VFR2019,
AS 4777.2:2015, IEC/EN 62109-1/-2, IEC/EN 61000-3-2/-3, IEC/EN-61000-6-
1/-2/-3/-4
Summary of Contents for HME-1000T-AU
Page 1: ...Version 1 2 June 2020...