HME-1000T/1200T/1350T/1500T-AU 

 

-  Take a complete inspection when restarting after a long time or prolonged stop. 

-  Please  dispose  the  equipment  properly  after  scrapping,  which  are  potentially  harmful  to  the 

environment, in accordance with the regulations in force in the country of installation. 

8. Compliance Consideration 

8.1 Earth Fault Alarm Notification 

This inverter complies with IEC 62109-2 clause 13.9 for earth fault alarm monitoring. 

If an Earth Fault Alarm occurs, the LED on the microinverter will light up solid red every 0.5 second. 

An  external  indication  of  earth  fault  alarm  can  be  provided  by  the  connecting  the  PV  System  to 
Hoymiles monitoring app/portal. For details of how to configure monitoring please refer to document 

HMP Operating Guide (Webpage) V2.0

  and 

HMP Operation Guide (APP)

.   

8.2 Power Quality Response Modes 

This  inverter  supports  the  following  power  quality  response  modes  as  per AS  4777.2:2015:  Power 
derating for voltage variation (Volt-Watt mode). 

The inverter output power varies in response to the voltage at its terminal. This mode can be enabled 
via gridprofile module on Hoymiles monitoring platform. Please refer to document 

HMP Operating 

Guide (Webpage) V2.0

  and 

HMP Operation Guide (APP)

  or contact Tech Support for more 

information 

8.3 DRM 

DRM is provided to support several demand response modes by giving control signals as below.   

 

 

This microinverter can support DRM0/5/6/7/8 by installed with DTU-Pro. The DRM interface is on the 
Hoymiles gateway DTU-Pro as follows. 

 

Summary of Contents for HME-1000T-AU

Page 1: ...Version 1 2 June 2020...

Page 2: ...control the production of a single photovoltaic module directly consequently improving the flexibility and reliability of the system About the Manual This manual contains important instructions for t...

Page 3: ...hlights 8 3 3 Terminals Introduction 8 3 4 Dimension mm 8 4 About Function 9 4 1 Work Mode 9 5 About Installation 9 5 1 Accessories 9 5 2 Installation Precaution 10 5 3 Space Distance Required 10 5 4...

Page 4: ...ification 22 8 2 Power Quality Response Modes 22 8 3 DRM 22 9 Technical Data 23 8 1 DC Input 23 8 2 AC Output 23 8 3 Efficiency Safety and Protection 24 8 4 Mechanical Data 24 8 5 Features 24 Appendix...

Page 5: ...below 2 About Safety 2 1 Important Safety Instructions The HME 1000T 1200T 1350T 1500T AU Microinverter is designed and tested according to international safety requirements However certain safety pr...

Page 6: ...onal protective equipment including gloves and eye protection during the installation Inform the manufacturer about non standard installation conditions Do not use the equipment if any operating anoma...

Page 7: ...at the interference will not occur in a particular installation To confirm that the radio or television reception is interfered by this equipment you can turn the equipment off and on If this equipmen...

Page 8: ...efficiency 96 70 CEC weighted efficiency 96 50 Static MPPT efficiency 99 80 Dynamic MPPT efficiency 99 76 in overcast weather Power factor adjustable 0 8 leading 0 8 lagging External antenna for stron...

Page 9: ...Grid Stand by There are several circumstance that Microinverter will stay in Standby mode The current condition is contradicted with Microinverter operating requirement No house loads or the Export co...

Page 10: ...sure to ensure ventilation and heat dissipation Note For some countries the DTU will be required to meet the local grid regulation e g G98 99 for UK etc 5 3 Space Distance Required If the microinverte...

Page 11: ...rating due to an increase in the microinverter internal temperature do not expose it to direct sunlight To avoid overheating always make sure the air flow around the inverter is not blocked Do not in...

Page 12: ...se install the microinverter at least 50cm above the ground roof for better communication with Hoymiles DTU Step 2 Complete the AC Connection A Attach the AC bus cable with the mounting rail and fix t...

Page 13: ...slot accordingly Tighten the screws and then tighten the cap back to the port Plug the upper cover back to the bus connector B Connect the other side of the AC end cable to the distribution box and w...

Page 14: ...install the DTU and set up the monitoring system Product information is subject to change without notice Please download reference manuals at www hoymiles com 6 Troubleshooting 6 1 Troubleshooting Li...

Page 15: ...ween the DTU and the microinverter If the communication is poor try to make some improvements 3 If the alarm occurs frequently and cannot be recovered contact your dealer or Hoymiles technical support...

Page 16: ...rid frequency change rate is within the acceptable range If no contact the local power operator or change the grid frequency change rate limit via Hoymiles monitoring system with the consent of the lo...

Page 17: ...correct 301 Hardware Error Code 301 1 If the alarm occurs accidentally and the microinverter can still work normally no special treatment is required 2 If the alarm occurs frequently and cannot be re...

Page 18: ...Flashing green five times 0 3s gap Start up success Flashing Red five times 0 3s gap Start up failure 2 Run Process Flashing Fast Green 1s gap Producing power Flashing Slow Green 2s gap Producing powe...

Page 19: ...lease return it to the factory for replacement 6 4 Routine Maintenance 1 Only authorized personnel are allowed to carry out the maintenance operations and are responsible to report any anomalies 2 Alw...

Page 20: ...unit 6 5 Replace Microinverter a How to remove the Microinverter De energize the AC branch circuit breaker Remove the PV panel from the racking and cover the panel Using a meter to measure and make s...

Page 21: ...particular the electronic components from violent shocks humidity vibration etc Please dispose the packaging elements in appropriate ways to avoid unforeseen injury It is the customer s responsibilit...

Page 22: ...ting the PV System to Hoymiles monitoring app portal For details of how to configure monitoring please refer to document HMP Operating Guide Webpage V2 0 and HMP Operation Guide APP 8 2 Power Quality...

Page 23: ...rter Refer to Hoymiles Warranty Terms Conditions for more information 8 1 DC Input 8 2 AC Output Model HME 1000T AU HME 1200T AU HME 1350T AU HME 1500T AU Commonly used module power W Up to 310 single...

Page 24: ...verter efficiency 96 70 96 70 96 70 96 70 CEC weighted efficiency 96 50 96 50 96 50 96 50 Nominal MPPT efficiency 99 80 99 80 99 80 99 80 Night time power consumption mW 50 50 50 50 Model HME 1000T AU...

Page 25: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 25 HME 1000T 1200T 1350T 1500T AU...

Page 26: ...2019 Hoymiles Converter Technology Co Ltd All rights reserved 26 HME 1000T 1200T 1350T 1500T AU Appendix 1 Installation Map...

Page 27: ...RING DIAGRAM 230VAC SINGLE PHASE GROUND NEUTRAL W AC DISTRIBUTION PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREEN G L1 PHASE L1 ETHERNET CONNECTION TO BROADBAND ROUTER CONNECTION T...

Page 28: ...IBUTION PANEL OR SUBPANEL METER AC BRANCH CABLE BROWN L BLUE N YELLOW GREEN G L1 L2 L3 ETHERNET CONNECTION TO BROADBAND ROUTER CONNECTION TO DTU POWER ADAPATER 5V DTU UP TO 24 HME 1500T AUs PHASE L1 P...

Reviews: