Maintenance
35
Water
Filtration
The
purpose
of
water
filtration
is
to
keep
the
Ice
Flaker
clean
and
operating
efficiently.
The
value
to
the
user
is
reduced
operating
cost
due
to
less
maintenance,
improved
performance
and
a
greater
return
on
investment
as
result
of
extended
asset
life.
There
are
three
primary
categories
of
contaminants
that
damage
and
cause
the
Ice
Flaker
to
operate
inefficiently.
They
are
listed
here
in
order
of
importance
with
regard
to
impact.
1.
Scale
2.
Sediment
3.
Chlorine
Scale
Scale
or
fouling
is
the
accumulation
of
unwanted
material
on
solid
surfaces
to
the
detriment
of
function.
Scale
is
primarily
made
up
of
calcium
and
magnesium
hardness
compounds.
It’s
estimated
that
scale
is
responsible
for
70%
of
unscheduled
maintenance,
inefficient
operation,
and
down
time.
Scale
forms
on
wetted
surfaces,
accumulates
in
tubing
and
fittings
and
interferes
with
operation.
Sediment
The
formation
of
scale
from
dissolved
minerals
is
made
worse
by
sediment.
Sediment
is
suspended
particles
of
dirt,
silt
and
other
fine
particulate
matter
that
act
as
a
catalyst
for
scale
to
form.
Sediment
can
be
detrimental
to
the
condition
and
performance
of
the
Ice
Flaker.
Particulates
cause
added
wear
on
parts
and
can
clog
valves
and
impede
flow.
The
effects
of
scale
and
sediment
can
be
very
destructive
to
the
Ice
Flaker.
Chlorine
Chlorine
is
the
most
common
disinfectant
used
to
kill
pathogenic
organisms
in
order
to
make
our
water
safe
to
drink.
However,
residual
free
chlorine
in
water
can
contribute
to
pitting,
rust
and
corrosion
of
stainless
steel.
If
not
removed
from
water,
chlorine
mixes
with
moisture
in
the
Ice
Flaker
and
Ice
bin
to
form
a
mild
hydrochloric
acid.
This
acid
can
cause
surface
rust
to
form
on
stainless
steel
surfaces
in
one
to
two
years.
Summary of Contents for 1000-RLE
Page 6: ...6 Engineering Guidelines Figure 1 ...
Page 40: ...40 Appendix Appendix Cut View 1000 RLE ...
Page 41: ...Appendix 41 Cut View 2000 RLE 3000 RLE ...
Page 42: ...42 Appendix Assembly Drawing 1000 RLE Ice Flaker CP750 Mobile Express Ice Bin ...
Page 43: ...Appendix 43 Assembly Drawing 2000 RLE Ice Flaker CP1500 Mobile Express Ice Bin ...
Page 44: ...44 Appendix Assembly Drawing 3000 RLE Ice Flaker CP2500 Mobile Express Ice Bin ...
Page 45: ...Appendix 45 Wiring Diagram Ice Flaker ...
Page 46: ...46 Appendix Wiring Diagram 230 3 60 Air Cooled Condensing Unit supplied by Howe Corporation ...
Page 47: ...Installation Service Manual For Use with Remote Single Condensing Unit RLE Rev Date 08 2014 ...
Page 48: ...Parts List 1000 RLE Non Replaceable Parts Item No Description Part No ...
Page 51: ...Parts List 2000 RLE 3000 RLE ...