Field
Installation
Evacuation
Do
not
use
the
refrigeration
compressor
to
evacuate
the
system.
Do
not
start
the
compressor
while
it
is
in
a
vacuum.
A
good,
deep
vacuum
pump
should
be
connected
to
both
the
low
and
high
side
evacuation
valves
with
copper
tube
or
high
vacuum
hoses
(1/4”
ID
minimum).
If
the
compressor
has
service
valves,
they
should
remain
closed.
A
deep
vacuum
gauge
capable
of
registering
pressure
in
microns
should
be
attached
to
the
system
for
pressure
readings.
A
shut
off
valve
between
the
gauge
connection
and
vacuum
pump
should
be
provided
to
allow
the
system
pressure
to
be
checked
after
evacuation.
Do
not
turn
off
vacuum
pump
when
connected
to
an
evacuated
system
before
closing
shut
off
valve.
The
vacuum
pump
should
be
operated
until
a
pressure
of
1,500
microns
absolute
pressure
is
reached
–
at
which
time
the
vacuum
should
be
broken
with
the
refrigerant
to
be
used
in
the
system
through
a
drier
until
the
system
pressure
rises
above
“0”
psig.
Refrigerant
used
during
evacuation
cannot
be
vented.
Reclaim
all
used
refrigerant.
Repeat
this
operation
a
second
time.
Open
the
compressor
service
valves
and
evacuate
the
entire
system
to
500
microns
absolute
pressure.
Raise
the
pressure
to
2
psig
with
the
refrigerant
and
remove
the
vacuum
pump.
Field
Wiring
All
field
wiring
must
be
in
compliance
with
local
and
national
codes.
Use
only
copper
conductors
of
the
appropriate
size.
1.
Install
disconnect
(not
supplied
by
factory).
2.
Connect
208
‐
230/1/60
power
to
the
two
black
wires
marked
“L1”
and
“L2”
in
the
junction
box
on
the
rear
of
the
Ice
Flaker.
3.
In
the
junction
box
there
are
two
red
wires
marked
“A”
and
“B”.
Remove
wire
nut.
4.
Connect
the
normally
‐
open
isolating
contacts
from
the
relay
mounted
in
the
condensing
unit
to
“A”
and
“B”.
5.
Locate
and
connect
Photo
Eye
sensors
to
the
matching
plug
inside
the
Ice
Flaker
enclosure
(see
p.24).
Summary of Contents for 1000-RLE
Page 6: ...6 Engineering Guidelines Figure 1 ...
Page 40: ...40 Appendix Appendix Cut View 1000 RLE ...
Page 41: ...Appendix 41 Cut View 2000 RLE 3000 RLE ...
Page 42: ...42 Appendix Assembly Drawing 1000 RLE Ice Flaker CP750 Mobile Express Ice Bin ...
Page 43: ...Appendix 43 Assembly Drawing 2000 RLE Ice Flaker CP1500 Mobile Express Ice Bin ...
Page 44: ...44 Appendix Assembly Drawing 3000 RLE Ice Flaker CP2500 Mobile Express Ice Bin ...
Page 45: ...Appendix 45 Wiring Diagram Ice Flaker ...
Page 46: ...46 Appendix Wiring Diagram 230 3 60 Air Cooled Condensing Unit supplied by Howe Corporation ...
Page 47: ...Installation Service Manual For Use with Remote Single Condensing Unit RLE Rev Date 08 2014 ...
Page 48: ...Parts List 1000 RLE Non Replaceable Parts Item No Description Part No ...
Page 51: ...Parts List 2000 RLE 3000 RLE ...