background image

INSTALLATION INSTRUCTIONS

LCN2750MV

CAUTION:

void your authority to use this equipment. 
This device complies with part 15 of the FCC Rules. Operation is 

subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation.

authority to use this equipment.

This equipment has been tested and found to comply with the limits for 

a Class B digital device, pursuant to part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses 

and can radiate radio frequency energy and, if not installed and used 

in accordance with the instructions, may cause harmful interference to 

radio communications. However, there is no guarantee that interference 

will not occur in a particular installation. If this equipment does cause 

harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged 

to try to correct the interference by one or more of the following 

measures:
—Reorient or relocate the receiving antenna.

—Increase the separation between the equipment and receiver.

—Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected.

—Consult the dealer or an experienced radio/TV technician for help.
CAN ICES-005 (B)/NMB-005 (B)

FCC NOTICE Class B

Fixture is equipped with universal volt driver 120-277V 
(ie. 120V, 208V, 240V or 277V)

PHASE TO NEUTRAL WIRING 120/277V

1.  Connect supply ground to fixture ground (green) lead.

2.  Connect supply common to fixture neutral (white) lead.

3.  Connect supply Vin to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no wires 
are pinched.

PHASE TO PHASE WIRING 208/240V

1.  Connect supply ground to fixture ground (green) lead.

2.  Connect supply L1 (Hot) to fixture neutral (white) lead.

3.  Connect supply L2 (Hot) to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no wires 

are pinched.