background image

2  Safety

2.1  Symbols

 Caution

This symbol warns against risk of injury. Please heed all instructions 

 designated by this symbol to prevent injuries and/or death.

 Attention

This symbol warns against property damage. Please heed the respective 

instructions to prevent risk of damage to the unit and its functions.

 Notice

This symbol denotes information about the economic use of the equipment 

or special tips.

2.2  Operational safety

The unit is built to conform to the state-of-the-art and is operationally safe. Despite 

every precaution being taken, potential and not immediately obvious risks always 

remain, for example:

 

Dangers when working with the electrical system

 

Parts (e.g. tools) can fall down below when working on the ventilation unit.

 

Malfunctions as a result of defective parts

 

Hazards from hot water when working on the hot water supply

Therefore:

 

Please read the operating instructions before unpacking, installing, commis-

sioning and before maintaining the equipment.

 

Store the operating instructions so that they are easily accessible.

 

Observe any attached information and warning signs.

 

Immediately replace damaged or removed informational and warning signs.

 

Follow the local safety and accident prevention regulations at all times.

 

Disconnect the power supply and wait at least 5 minutes before opening the 

unit.

 

When working in the unit, take precautions against unprotected, sharp metal 

edges.

 

The unit may only be installed, operated and serviced by authorised, trained 

and instructed skilled personnel:

 

Specialists as defined by these operating instructions are those persons 

who, based on their training, knowledge and experience as well as their 

knowledge of the relevant regulations and guidelines, can carry out the work 

assigned to them and recognise potential hazards.

 

Unauthorised reconfiguration or modification of the unit is not permitted.

4

TopVent

®

 TV

Design, installation and operation

Safety

4 216 284-en-05

Summary of Contents for TopVent TV Series

Page 1: ...TopVent TV Design installation and operation TopVent TV Recirculation unit for heating spaces up to 6 m in height...

Page 2: ...nd data 9 4 5 Dimensions and weights 9 4 6 Specification text 9 5 Transport and installation 10 5 1 Delivery 10 5 2 Requirements for the installation site 10 5 3 Installation 11 5 4 Hydraulic installa...

Page 3: ...and above this use is considered to be not as intended The manufacturer can accept no liability for damage resulting from improper use 1 2 User group The units are only allowed to be installed operate...

Page 4: ...read the operating instructions before unpacking installing commis sioning and before maintaining the equipment Store the operating instructions so that they are easily accessible Observe any attached...

Page 5: ...sts of the following components Heat exchanger consisting of copper tubes and aluminium fins Axial fan with energy saving EC motor and flow optimised fan blades infinitely variable maintenance free an...

Page 6: ...tact switch The connected units are switched on via door contact if the door is open digital input Adjusting the fan speed The required speed can be infinitely adjusted Pump or valve control The EasyT...

Page 7: ...its switch on Upon reaching the setpoint value the units switch off again Adjusting the fan speed The required speed can be infinitely adjusted Fig 3 EasyTronic TV room temperature controller EasyTron...

Page 8: ...1 70 Supply voltage VAC 230 230 230 Frequency Hz 50 50 50 Max mounting height m 5 5 5 5 5 5 Max horizontal reach m 14 0 22 0 25 0 Table 5 Technical data 4 3 Heat output Temperature of the heating med...

Page 9: ...TV Recirculation unit for heating spaces up to 6 m in height Sturdy casing made of ABS with pigment additive for UV protection front in RAL 9016 Traffic white and back in RAL 7037 Dusty grey heat exch...

Page 10: ...veries and possible transport damage immediately in writing 5 2 Requirements for the installation site Position the units according to the system layout Comply with the minimum and maximum distances A...

Page 11: ...opening Position the retaining bracket 3 over the openings Insert M10 screws 4 into the bushes Turn the retaining bracket to the desired position in relation to the unit Tighten the screws to secure t...

Page 12: ...the air distribution Insulate the hydraulic lines Hydraulically balance the pipework for the the individual units within a control zone to ensure even distribution Attention Danger of damaging the un...

Page 13: ...d connection boxes Install the connection box close to the unit distance 0 5 m Options for EasyTronic EC Wire the external room temperature sensor to the EasyTronic EC Wire the door contact to the Eas...

Page 14: ...E 2x1 5 mm 2 1 2x1 0 mm 13 44 L PE L N PE AIN GND N 1 2 3G1 5 mm min 1 2 GNYE 2x1 0 mm 1 2 PE N L 1 2 PE N L 1 2 1 2 L N PE Connection box by the installer TopVent TV Door contact Pump or valve Extern...

Page 15: ...x1 0 mm 1 2 N 1 2 PE L N 2x1 5 mm N L PE L N PE AIN GND N 1 2 3G1 5 mm min 1 2 GNYE 2x1 0 mm 1 2 PE N L 1 2 PE N L 1 2 1 2 L N PE EasyTronic TV Connection box by the installer TopVent TV further TopVe...

Page 16: ...e casing base e g using a screw driver Break through the casing base along the perforation Insert the cables through this opening Connect the cables to the connectors Screw the base onto a flush mount...

Page 17: ...ced Are all the control components installed and wired Are all of the respective trade groups installer electrician etc present at the scheduled time Are the system operating personnel present for tra...

Page 18: ...en working on electrical systems When working in the unit take precautions against unprotected sharp metal edges Immediately replace damaged or removed informational and warning signs Following mainte...

Page 19: ...of fatal injury from directly touching live parts even after the unit is switched off Only open the unit after waiting 5 minutes Drain the heating medium circuit Dismantle all media connections Disco...

Page 20: ...90 Vaduz Liechtenstein Tel 423 399 24 00 info klimatechnik hoval com www hoval com United Kingdom Hoval Ltd Northgate Newark Notts NG24 1JN Tel 01636 672711 hoval hoval co uk www hoval co uk 20 421628...

Reviews: