Advanced User Instructions 

430294ENG-Jun02

 

 

 
Language 

 
The room station is programmed in three 
languages English, German and French. To 
change the language press           or           key 
for 5 seconds. Once the language appears the 
keys can be used to change languages. 
 
                                    or            
 
 
 
 
Works setting: ENGLISH 
 
The previous display will return in a few 
seconds. 
 

1 - Clock setting 

 
The following functions can be set: 
 

Time (minutes, hours) 

Day 

Month 

Year 

 
The clock can be set to automatically change 
over from summer to winter time by a parameter 
in the service level of the central unit. 
 

Changing clock settings 

The clock can be changed by using 

         key 

and then the       and      keys to increase or 
decrease the values. 
 
            - 

Time

 

  
Change with: 
       to increase 
       to decrease  
Setting Range: 

 

 00:00 … 23:59 

                  
 
            - 

Date

 

 

Change with: 
       to increase 
       to decrease  
Setting Range: 

 

 1 … 31 

                  
 
            - 

Month

 

 

Change with: 
       to increase 
       to decrease  
Setting Range: 

 

 1 … 12 

                  
 
            - 

Year

 

 

Change with: 
       to increase 
       to decrease  
Setting Range: 

 

 1995 … 2030 

                  
 
            - Return to default display 
 
If the

 

         key is not pressed the default display 

will return after 2 minutes. It is possible to return 
to the default display at any time using the 

       

information key. 
 

2 - Time clock level 

 
In the time clock level the individual program 
times can be customized. Standard heating 
programs  1, 2 and 3 can be called up as desired 
and overwritten with different switch times and 
temperatures. Each standard program can thus 
be configured individually and stored under the 
same program number so that three different 
programs are available on demand. These can 
then simply be called up in the user operating 
level see page 6 for setting of the automatic 
program. 
Note: Programming of room temperatures is only 

possible if the relevant parameter has 
been enabled in the service level by an 
engineer. 

 

If this has not been done it is only possible 
to change the on / off times. In this case 
the room temperature will be the works 
setting of 20ºC or the corrected value 
which has been set in the user level. 
 
The standard programs are lost when 
overwritten by customized programs. 
These are cancelled after a reset and 
replaced by the standard programs and  
therefore have to be recreated if needed. 
 

Summary of Contents for TopTronic RS-30

Page 1: ...User Instructions For TopTronic RS 30 430294ENG Jun02 Hoval Ltd Northgate Newark Nottinghamshire NG24 1JN Phone 01636 672711 Fax 01636 673532...

Page 2: ...mperature 6 Heating program 7 Calorifier charging 9 Advanced user instructions Language 10 Clock setting 10 Time clock level 10 Time clock programming 11 Block programming 14 Table program 1 settings...

Page 3: ...mperatures actual values and diagnostic fault messages of the boiler Operation of the unit is easy to understand and is limited to a minimum of operating elements which are separated for user and adva...

Page 4: ...d hold or 5 30o C Heating Off manual summer operation press and hold or On Off Automatic or Calorifier charging and simultaneously ON or OFF Automatic programs 1 3 and simultaneously or 1 2 3 Switchin...

Page 5: ...indication system which has priority over all other indications and remain active until the fault is rectified Faults concerning the firing unit must be rectified in accordance with operating manual i...

Page 6: ...below press or Display for heating operation Works setting 20o C Adjustment range 5o C 30o C press to increase to decrease Default screen automatically returns after 4 seconds If in reduced operation...

Page 7: ...certain time for a one off event press and hold Display for party program For example At 20 15 the heating needs to be extended by 3 hours to 23 15 press to increase to decrease Adjustment range 0 5 1...

Page 8: ...o decrease Adjustment range 0 5 10h It should be noted that the adjustment is from the time of alteration and not an extension of the automatic program 1 2 or 3 The default display will return after 4...

Page 9: ...ting off hot water on press and hold The default display will return after 4 seconds During this operation method the will blink To cancel heating off program The heating off program can be cancelled...

Page 10: ...not pressed the default display will return after 2 minutes It is possible to return to the default display at any time using the information key 2 Time clock level In the time clock level the indivi...

Page 11: ...ater heating is switch off The temperature is set in the room level and cannot be changed for each cycle Entering the time clock level Entering this level is achieved by simply pressing the key The pr...

Page 12: ...ly when set in service level parameters Change with Next cycle Cycle 3 Monday ON Change with Next setting OFF Change with Next setting TEMP only when set in service level parameters Change with Next c...

Page 13: ...s note the appropriate values in the tables Canceling of individual heating cycles If necessary individually created cycles can be cancelled After selecting the required cycle by pressing the key seve...

Page 14: ...m to which it is to be copied The key is used to complete the copy The procedure is shown in further detail by the illustration below Note It is not possible to copy heating programs to hot water prog...

Page 15: ...day While in the time clock see page 13 the current day can be copied to another day by using the key two or more times to select the target day The key is used to complete the copy of the current day...

Page 16: ...a the correction keys or for one of the cycles This change will then effect all other heating cycles as shown in the below example Original cycle temperatures New cycle temperatures As the temperature...

Page 17: ...0 20o C Tue 6 00 8 00 16 00 22 00 Wed 6 00 8 00 20 o C 16 00 22 00 20 o C Wed 6 00 8 00 16 00 22 00 Thur 6 00 8 00 20 o C 16 00 22 00 20 o C Thur 6 00 8 00 16 00 22 00 Fri 6 00 8 00 20 o C 16 00 22 00...

Page 18: ...on 6 00 22 00 Tue 6 00 22 00 20 o C Tue 6 00 22 00 Wed 6 00 22 00 20 o C Wed 6 00 22 00 Thur 6 00 22 00 20 o C Thur 6 00 22 00 Fri 6 00 22 00 20o C Fri 6 00 22 00 Sat 6 00 22 00 20o C Sat 6 00 22 00 S...

Page 19: ...0 00 23 55 Tue 6 00 23 00 20o C Tue 00 00 23 55 Wed 6 00 23 00 20 o C Wed 00 00 23 55 Thur 6 00 23 00 20 o C Thur 00 00 23 55 Fri 6 00 23 00 20 o C Fri 00 00 23 55 Sat 6 00 23 00 20o C Sat 00 00 23 55...

Page 20: ...Works setting On Adjustment range On or Off Change with keys or On Hot water control possible Off No Hot water control Burner hours run Works setting 000000 00h Range 0 99999999 Number of burner start...

Page 21: ...between the three clock programs for hot water see pages 17 to 19 for settings Boiler circuit clock program Works setting Program 2 Options Program 1 Program 2 Program 3 Change with or With this para...

Page 22: ...ption is set in the service level the value will blink and is constantly corrected In this case it must not be manually altered Recommended values Floor heating 0 3 1 0 Radiator heating 1 2 2 0 Convec...

Page 23: ...On On 3 Burner hours run 000000 00 999999 59 000000 00 4 Burner starts 00000000 99999999 00000000 5 Holiday program start 01 01 31 12 Not set 6 Holiday program finish 01 01 31 12 Not set 7 Clock progr...

Page 24: ...6 h 2 h 7 Heating maximum temp 40 90 o C 80 o C 8 Hot water maximum temp 40 60 o C 60 o C 9 Frost protection 20 10 o C 0 o C 10 Summer switch off 10 30 o C 17 o C 11 Protection against Legionella Off...

Page 25: ...Secure the back plate with the screws provided The data bus cable must be threaded through the lower part of the back plate With a data bus cable of over 50m cable of types JY ST 2x0 6 must be used T...

Reviews: