25
4 220 456 / 02
TECHNICAl INFORMATION
3.3.3 UltraGas
®
2 (530-800)
Type
(530)
(620)
(700)
(800)
• Nominal heat output at 80/60 °C, natural gas
kW
100-497
125-580
132-653
150-743
• Nominal heat output at 50/30 °C, natural gas
kW
110-533
136-622
146-703
166-804
• Nominal heat output at 80/60 °C, propane
2)
kW
-
-
-
-
• Nominal heat output at 50/30 °C, propane
2)
kW
-
-
-
-
• Nominal heat input with natural gas
1)
kW
101-506
124-591
134-668
151-759
• Nominal heat input with propane
2)
kW
-
-
-
-
•
Operating pressure heating min./max. (PMS)
bar
1/6
1/6
1/6
1/6
•
Max. operating temperature (T
max
)
°C
95
95
95
95
• Boiler water content (V
(H20)
)
l
571
536
509
831
• Flow resistance boiler
See diagram
•
Minimum circulation water quantity
l/h
-
-
-
-
• Boiler weight (without water capacity, incl. cladding)
kg
978
1050
1100
1370
•
Boiler efficiency at 80/60 °C in full-load operation (NCV/GCV)
3)
%
98.2/88.5
98.2/88.5
98.2/88.5
98.3/88.6
•
Boiler efficiency at 30% partial load operation (EN 15502) (NCV/GCV)
3)
%
109.1/98.3
109.0/98.2
108.9/98.1
109.1/98.3
•
Room heating energy efficiency
- without control
ηs
%
-
-
-
-
- with control
ηs
%
-
-
-
-
- with control and room sensor
ηs
%
-
-
-
-
• NOx class (EN 15502)
6
6
6
6
• Nitrogen oxide emissions (EN 15502) (GCV)
NOx
mg/kWh
33
33
40
36
• Carbon monoxide emissions at 50/30 °C
4)
CO
mg/Nm
3
20
24
26
23
• O
2
content in flue gas min./max. output
5)
%
5.9/5.9
5.9/6.0
6.0/5.7
6.0/5.8
• CO
2
content in flue gas at min./max. output
%
8.6/8.6
8.5-8.5
8.5/8.7
8.5/8.6
• Heat loss in standby mode
Watts
1000
1000
1000
1200
• Dimensions
See dimensional drawing
•
Gas flow pressure min./max.
- Natural gas E/LL
mbar
17.4-80
17.4-80
17.4-80
17.4-80
- Liquid gas
mbar
-
-
-
-
• Gas connection values at 15 °C/1013 mbar:
- Natural gas E - (Wo = 15.0 kWh/m
3
) NCV = 9.97 kWh/m
3
m
3
/h
10.1-50.8
12.4-59.3
13.4-67.0
15.1-76.1
- Natural gas LL - (Wo = 12.4 kWh/m
3
) NCV = 8.57 kWh/m
3
m
3
/h
11.8-59.0
14.5-69.0
15.6-77.9
17.6-88.6
-
Propane (NCV = 25.9 kWh/m
3
)
m
3
/h
-
-
-
-
• Operating voltage
V / Hz
1x230/50
1x230/50
1x230/50
1x230/50
• Electrical power consumption min./max.
Watts
67/805
63/831
67/1060
94/1012
• Standby
Watts
5
5
5
7
• Type of protection
IP
20
20
20
20
• Permitted ambient temperature during operation
°C
5-40
5-40
5-40
5-40
• Sound power level
- Heating noise (EN 15036 part 1) (room air dependent)
dB(A)
77
75
76
-
- Flue gas noise radiated from the mouth
(DIN 45635 part 47) (room air dependent/independent of room air)
dB(A)
-
-
-
-
- Sound pressure level heating noise (depending on installation conditions)
6)
67
65
66
-
• Condensate quantity (natural gas) at 50/30 °C
l/h
39
51
48
57
• pH value of the condensate (approx.)
4.2
4.2
4.2
4.2
• Construction
B23P, C53, C63
• Flue gas system
- Temperature class
T120
T120
T120
T120
-
Flue gas mass flow at nominal heat input (dry)
kg/h
800
933
1055
1198
-
Flue gas mass flow at lowest heat input (dry)
kg/h
159
196
211
238
- Flue gas temperature at nominal output and operation 80/60 °C
°C
67
68
69
66
- Flue gas temperature at nominal output and operation 50/30 °C
°C
45
47
49
44
- Flue gas temperature at lowest heat output and operation 50/30 °C
°C
28
28
29
28
-
Max. permissible temperature of the combustion air
°C
48
48
48
48
- Flow rate combustion air
Nm
3
/h
654
764
863
981
-
Maximum supply pressure for supply air and flue gas line
Pa
130
130
130
130
-
Maximum draught/negative pressure at flue gas outlet
Pa
-50
-50
-50
-50
1)
Data related to NCV. The boiler series is tested for EE/H setting. With a factory setting to a Wobbe value
of 15.0 kWh/m
3
, operation in the Wobbe value range from 12.0 to 15.7 kWh/m
3
is possible without resetting.
2)
Data related to NCV
3)
Conversion acc. to EN 15502-1, Appendix J
4)
Data related to 3 % of O
2
5)
Values at determination of technical data during approval
6)
Compare notice for engineering