
4
W
Wa
arrn
niin
ng
g::
E
En
ns
su
urre
e tth
ha
att y
yo
ou
urr a
ap
pp
plliia
an
nc
ce
e h
ha
as
s n
no
ott b
be
ee
en
n
d
da
am
ma
ag
ge
ed
d d
du
urriin
ng
g ttrra
an
ns
sp
po
orrtt ((b
brro
ok
ke
en
n s
se
ea
all o
orr d
do
oo
orr,,
e
ettc
c..)).. IIff y
yo
ou
u n
no
ottiic
ce
e a
an
ny
y k
kiin
nd
d o
off d
da
am
ma
ag
ge
e,, c
co
on
ntta
ac
ctt
y
yo
ou
urr rre
etta
aiille
err b
be
effo
orre
e u
us
se
e..
Ensure that:
- the electrical power has sufficient voltage.
- the power cable is in good condition
-
the diameter of the wires complies with
installation requirements.
- your electrical installation is equipped with
protection of at least 16 amperes.
If in doubt, consult an electrician.
The electrical connections must be made before
installing the appliance in its housing.
Electrical safety must be guaranteed by correct
installation in the housing. During installation and
maintenance operations, the appliance must be
unplugged from the mains; the circuit-breaker
must be disconnected or the fuses must be
removed.
The appliance must be connected using a
(standardised) power cable equipped with
3 1.5 mm² conductors (phase + n ground),
connected to a single phase 220-240 V ~ network
using an IEC 60083 standardised plug (phase +
n ground) or in accordance with installation
requirements. The safety wire (green-yellow) is
connected to the appliance’s
terminal and
must be connected to the installation ground.
In order to easily locate the reference information
for your appliance, we recommend that you make
a note of it on the “After-Sales Service” page.
If the appliance has an electrical connection, it
must remain accessible after the appliance has
been built in.
The oven’s neutral (blue wire) must be connected
to the network’s neutral.
It must be possible to disconnect the appliance
from the power supply, either using a plug or by
fitting a switch on the fixed wiring system in
accordance with installation rules.
If the power cable is damaged, it should be
replaced by the manufacturer, its after-sales
service department or by a similar qualified
person to avoid danger.
W
Wa
arrn
niin
ng
g::
W
We
e c
ca
an
nn
no
ott b
be
e h
he
elld
d rre
es
sp
po
on
ns
siib
blle
e ffo
orr a
an
ny
y
a
ac
cc
ciid
de
en
ntt rre
es
su
ullttiin
ng
g ffrro
om
m a
a n
no
on
n--e
ex
xiis
stte
en
ntt,, ffa
au
ulltty
y o
orr
iin
nc
co
orrrre
ec
ctt g
grro
ou
un
nd
d..
IIff tth
he
erre
e a
arre
e a
an
ny
y iirrrre
eg
gu
ulla
arriittiie
es
s w
wiitth
h tth
he
e o
ov
ve
en
n,, u
un
np
pllu
ug
g
tth
he
e a
ap
pp
plliia
an
nc
ce
e o
orr rre
em
mo
ov
ve
e tth
he
e ffu
us
se
e c
co
orrrre
es
sp
po
on
nd
diin
ng
g
tto
o tth
he
e o
ov
ve
en
n iin
nlle
ett c
co
on
nn
ne
ec
cttiio
on
n w
wiirre
e..
Before connection
Electrical connections
Installation