7 of 39
Indesit
Company
Service Manual UK
English
Thermistor - Resistance Chart
Fault Notes
•
Filling
After the initial drain period, it is normal at the start of a cycle for the machine to pause for a period
before filling.
•
Heating Element
An open circuit heating element can display either the heating time out fault code or the open
circuit heater fault code (
F8
&
F10
), depending on the cycle in progress or the phase of the cycle
when the heater fails.
If a dishwasher has an open circuit heating element, the machine may run for up to 75 minutes
before a fault code will display.
It is recommended before a module is replaced or when the fault is not obvious, the heating
element is tested for continuity and resistance to Earth at its terminals,
with the heater
disconnected
.
continued...
Temperature
in degrees C
Resistance
in K Ohms
Temperature
in degrees C
Resistance
in K Ohms
- 40
24751.661
50
146.215
- 35
17127.169
55
117.828
- 30
12014.762
60
95.420
- 25
8524.305
65
77.718
- 20
6113.811
70
63.584
- 15
4435.437
75
52.260
- 10
3249.216
80
43.166
- 5
2403.515
85
35.808
0
1794.358
90
29.828
+ 5
1351.294
95
24.961
10
1025.870
100
20.955
15
785.018
105
17.668
20
605.252
110
14.951
25
470.000
115
12.695
30
367.480
120
10.824
35
289.186
125
9.259
40
229.014
45
182.485