background image

GB

13

Installation

!

 Before operating your new appliance please read this instruction booklet 

carefully. It contains important information for safe use, installation and care 

of the appliance.

!

 Please keep these operating instructions for future reference. Pass them on 

to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can become a choking 

or suffocation hazard (see Precautions and tips).

!

 The appliance must be installed by a qualified professional according to the 

instructions provided. Incorrect installation may cause harm to people and 

animals or may damage property.

!

 This unit may be installed and used only in permanently ventilated rooms 

in accordance with current national regulations. The following requirements 

must be observed:

•  The room must be equipped with an air extraction system that expels 

any combustion fumes. This may consist of a hood or an electric fan that 

automatically starts each time the appliance is switched on.

In a chimney stack or branched flue. 

(exclusively for cooking appliances)

Directly to 

the Outside

•  The room must also allow proper air circulation, as air is needed for 

combustion to occur normally. The flow of air must not be less than 2 m

3

/h 

per kW of installed power.

The air circulation system may take air directly 

from the outside by means of a pipe with an 

inner cross section of  at least 100 cm

2

; the 

opening must not be vulnerable to any type 

of blockages.

The system can also provide the air needed for 

combustion indirectly, i.e. from adjacent rooms 

fitted with air circulation tubes as described 

above. However, these rooms must not be 

communal rooms, bedrooms or rooms that 

may present a fire hazard.

•  Intensive and prolonged use of the appliance may necessitate 

supplemental ventilation, e.g. opening a window or increasing the power 

of the air intake system (if present).

•  Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, 

rooms containing LPG cylinders must also be equipped with vents to allow 

gas to escape in the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored in rooms or 

storage areas that are below ground level (cellars, etc.). It is advisable to 

keep only the cylinder being used in the room, positioned so that it is not 

subject to heat produced by external sources (ovens, fireplaces, stoves, 

etc. ) which could raise the temperature of the cylinder above 50°C.

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

Fitting the appliance

The following precautions must be taken when installing the hob:

•  Kitchen cabinets adjacent to the appliance and taller than the top of the 

hob must be at least 200 mm from the edge of the hob.

•  Hoods must be installed according to their relative installation instruction 

manuals and at a minimum distance of 650 mm from the hob (see figure).

•  Place the wall cabinets adjacent to the hood at a minimum height of 420 

mm from the hob (see figure). 

If the hob is installed beneath a wall cabinet, 

the latter must be situated at a minimum of 700 

mm above the hob.

Before the installation remove the grids and burners from the hob and turn it 

upside down, making sure you don’t damage the thermocouples and spark 

plugs.

Apply the seals that come with the 

appliance along the outer edges of 

the hob to prevent any passage of air, 

humidity and water (see Figure).

For proper application make sure the 

surfaces to be sealed are clean, dry and 

free of any grease/oil.

•  The installation cavity should have the dimensions indicated in the figure.

  Fastening hooks are provided, allowing you to fasten the hob to tops that 

are between 20 and 40 mm thick. To ensure the hob is securely fastened 

to the top, we recommend you use all the hooks provided.

555 mm

55 mm

475 mm

Hook fastening diagram

     

Hooking position for top 

H=20mm

     Hooking position for top 

H=30mm

 

 

   

Front

     

Hooking position for top 

H=40mm

     

Back

! Use the hooks contained in the “accessory pack”.

600mm min.

420mm min.

650mm min.

Summary of Contents for PKL 752 T/IX/HA

Page 1: ...e e rimedi 12 Contents Operating Instructions 1 Warnings 2 Assistance 4 Description of the appliance 5 Installation 13 Start up and use 17 Precautions and tips 17 Maintenance and care 18 Troubleshooting 18 PKL 752 T IX HA Türkçe Çalıştırma Talimatları OCAK IZGARASI İçindekiler Çalıştırma Talimatları 1 Uyarılar 3 Teknik Servis 4 Cihazın tanıtımı 5 Kurulum 20 Başlangıç ve kullanım 24 Önlemler ve tav...

Page 2: ...raelettrica ancora caldi L apparecchio non è destinato a essere messo in funzione per mezzo di un temporizzatore esterno oppure di un sistema di comando a distanza separato ATTENZIONE l uso di protezioni del piano inappropriate può causare incidenti Warnings WARNING The appliance and its accessible parts become hot during use Care should be taken to avoidtouchingheatingelements Childrenlessthan8 y...

Page 3: ...arafından yapılamaz UYARI Ocak ızgarasında yağlı pişirme yaparken gözetlememetehlikeliolabilirveyangınayolaçabilir Yangını suyla söndürmeyi ASLA denemeyin cihazı kapatın ve alevi vb bir örtü veya yangın battaniyesiyle örtün UYARI Yangıntehlikesi öğeleripişirmeyüzeylerinde saklamayın UYARI Cam seramikteki yüzeyde çatlak varsa elektrik çarpması tehlikesini önlemek için cihazı kapatın Cihazüzerindeas...

Page 4: ...nodopera le parti di ricambio originali il trasporto dell elettrodomestico non riparabile in loco Inoltre qualora l elettrodomestico non sia riparabile la garanzia prevede lasostituzioneaprezzoagevolatoinfunzionedell anzianitàdelprodotto Al costo di 14 25 centesimi di Euro al minuto iva inclusa dal Lun al Ven dalle 08 00 alle 18 30 il Sab dalle 08 00 alle 13 00 e di 5 58 centesimi di Euroalminuto ...

Page 5: ... 2 GAS BURNERS 3 Control Knobs for GAS BURNERS 4 Ignition for GAS BURNERS 5 SAFETY DEVICES GASBURNERSdifferinsizeandpower Usethediameterofthecookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS and adjust the size of the flame GASBURNERIGNITIONenablesaspecificburnertobelitautomatically SAFETY DEVICE stops the gas flow if the flame is accidentally extinguished 5...

Page 6: ...ccanica se già esistente I gas di petrolio liquefatti più pesanti dell aria ristagnano verso il basso QuindiilocalicontenentibidonidiGPLdebbonoprevederedelleaperture versol esternocosìdapermetterel evacuazionedalbassodelleeventuali fughe di gas Pertanto i bidoni di GPL siano essi vuoti o parzialmente pieni non debbono essere installati o depositati in locali o vani a livello più basso del suolo ca...

Page 7: ...non deve subire piegature o compressioni Il cavo deve essere controllato periodicamente e sostituito solo da tecnici autorizzati vediAssistenza L azienda declina ogni responsabilità qualora queste norme non vengano rispettate Collegamento gas Il collegamento dell apparecchio alla tubazione o alla bombola del gas dovrà essere effettuato come prescritto dalle Norme Nazionali in vigore solo dopo esse...

Page 8: ... minimo non si abbiano spegnimenti dei bruciatori 4 Negli apparecchi provvisti del dispositivo di sicurezza termocoppia in caso di mancato funzionamento del dispositivo con bruciatori al minimo aumentare la portata dei minimi stessi agendo sulla vite di regolazione 5 Effettuatalaregolazione ripristinateisigillipostisuiby passconceralacca o materiali equivalenti 6 Nel caso di manopole con regolazio...

Page 9: ...entazione Nominale mbar Minima mbar Massima mbar 28 30 20 35 37 25 45 20 17 25 Rapido Ridotto RR Semi Rapido S Ausiliario A Tripla Corona TC 100 75 55 130 0 70 0 40 0 40 1 50 2 60 1 65 1 00 3 30 39 28 28 61 80 64 50 65x2 189 120 73 240 186 118 71 236 2 60 1 65 1 00 3 60 122 H3 96 Z 79 6 103x2 248 157 95 343 A 15 C e 1013 25 mbar gas secco Propano P C S 50 37 MJ Kg Butano P C S 49 47 MJ Kg Naturale...

Page 10: ...e sempre recipienti a fondo piatto e con coperchio Al momento dell ebollizione ruotare la manopola fino alla posizione di minimo Rapido Ridotto RR Semi Rapido S Ausiliario A Tripla Corona TC 24 26 16 20 10 14 24 26 Ø Diametro recipienti cm Bruciatore Per identificare il tipo di bruciatore fate riferimento ai disegni presenti nel paragrafo Caratteristiche dei bruciatori ed ugelli Per la massima sta...

Page 11: ... volte più rapida e consente di salvare un terzo di energia Manutenzione e cura Escludere la corrente elettrica Prima di ogni operazione isolare l apparecchio dalla rete di alimentazione elettrica Pulizia del piano di cottura Le parti smaltate e in vetro vanno lavate con acqua calda e detergente neutro L acquacalcareaodetergentiaggressivipotrebberolasciaremacchiesulle superficiinacciaioinox serima...

Page 12: ... vicinanze del piano Lafiammanonrimaneaccesanelleversioniconsicurezza Avete controllato se Non avete premuto a fondo la manopola Non avete mantenuto premuta a fondo la manopola per un tempo sufficiente ad attivare il dispositivo di sicurezza Sono ostruiti i fori di fuoriuscita del gas in corrispondenza del dispositivo di sicurezza Il bruciatore in posizione di minimo non rimane acceso Avete contro...

Page 13: ...erefore roomscontainingLPGcylindersmustalsobeequippedwithventstoallow gas to escape in the event of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or storage areas that are below ground level cellars etc It is advisable to keep only the cylinder being used in the room positioned so that it is not subject to heat produced by external s...

Page 14: ...le must not be bent or compressed Thecablemustbecheckedregularlyandreplacedbyauthorisedtechnicians only seeAssistance The manufacturer declines any liability should these safety measures not be observed Gas connection The appliance should be connected to the main gas supply or to a gas cylinder in compliance with current national regulations Before carrying out the connection make sure the cooker ...

Page 15: ...aveasafetydevice thermocouple fitted Ifthedevice fails to work when the burners are set to the low flame setting increase this low flame setting using the adjusting screw 5 Oncetheadjustmenthasbeenmade replacethesealsontheby passes using sealing wax or a similar substance 6 In the event of discrete adjustment knobs with LED visualisation turn the knob to the minimum power setting them remove it an...

Page 16: ...118 71 236 2 60 1 65 1 00 3 60 122 H3 96 Z 79 6 103x2 248 157 95 343 At 15 C and 1013 25 mbar dry gas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S 37 78 MJ m Table 1 Liquid Gas Natural Gas Supply pressures Burner Diameter mm Thermal Power kW p c s Nominal Reduced By pass 1 100 mm Nozzle 1 100 mm Nozzle 1 100 mm Flow g h Flow l h Thermal Power kW p c s Thermal Power kW p c s Nom...

Page 17: ...d and that each pan is placed centrally over the burner Pan handles should be positioned in line with one of the support bars on the pan support grid Panhandleshouldbepositionedsonottoprotrudebeyondthefrontedge of the hob The more variable aspect in terms of pan stability can often be the pan itself or the positioning of that pan during use Well balanced pans with flat bases that are placed centra...

Page 18: ...ot use flammable products Do not leave acid or alkaline substances such as vinegar mustard salt sugar or lemon juice on the hob Cleaning the hob parts Clean the enamelled and glass parts only with soft cloth or sponge Grids burner caps and burners can be removed to be cleaned Clean them by hand with warm water and non abrasive detergent removinganyfoodresiduesandcheckingthatnoneoftheburneropenings...

Page 19: ...e cookware is unstable Check to make sure that The bottom of the cookware is perfectly flat The cookware is positioned correctly at the centre of the burner The pan support grids have been positioned correctly ...

Page 20: ...PGsilindirleribulunanodalaraayrıcasızıntıdurumundagazınçıkmasını sağlayan havalandırmalar takılmalıdır Sonuç olarak LPG silindirleri kısmenyadatamamenzeminseviyesininaltındakiodalardaveyasaklama alanlarında kurulmamalı veya saklanmamalıdır bodrum vb Odada yalnızca kullanılan silindirin tutulması silindir sıcaklığını 50 C üzerine yükseltebilen harici kaynaklar fırınlar şömineler sobalar vb tarafınd...

Page 21: ...an değiştirilmelidir Yardım bölümüne bakın Buemniyetönlemlerineuyulmadığıtakdirdeüreticisorumlulukkabuletmez Gaz bağlantısı Aygıt yürürlüktekiulusaldüzenlemelereuygunşekildeanagazbeslemesine veya gaz silindirine bağlanmalıdır Bağlantıyı yapmadan önce fırının kullanmak istediğiniz gaz beslemesine uygun olduğundan emin olun Uygun değilse Farklı gaz türlerine uyarlama paragrafından belirtilen talimat...

Page 22: ...rlerin sönmediğinden emin olunuz 4 Emniyet aygıtı olan cihazlarda ısı pili brülörler minimum konumdayken bu aygıtın çalışmaması durumunda ayar vidasına müdahale ederek minimumları yükseltiniz 5 Ayar işlemi bittiğinde by pass lar üzerinde yer alan mumlu ya da benzer malzemeli mühürleri eski haline getiriniz Doğalgaz kullanımı durumunda ayar vidasının saat dönüş yönünün tersine gevşetilmesi gerekir ...

Page 23: ... 100 mm Meme 1 100 mm Tasima gücü g saat Tasima gücü l saat Çap mm Çizelge 1 Sıvı gaz Doğal gaz Brülör Termik güç kW üst ısı gücü Nominal Meme 1 100 mm 15 C ve 1013 25 mbar da kuru gaz Propan P C S 50 37 MJ Kg Bütan P C S 49 47 MJ Kg Doğal P C S 37 78 MJ m3 Azaltılmış Hızlı RR Yarı Hızlı S Yardımcı A Üç Taçlý TC 10 20 742 g h G30 728 g h G31 PKL 752 T IX HA Sınıf II2H3 Model Gaz bölüm Elektrik böl...

Page 24: ...larının tutacaklarının kap desteklerinin ızgaralarından birisi ile hizalı olmasına dikkat ediniz Pişirme kaplarının tutacaklarını pişirme tezgahının önüne taşmayacak şekilde yerleştiriniz Tencerelerle ilgili en fazla değişkenlik gösterecek husus tencerenin kendisiyle ilgili olabilir Veya kullanım sırasında nasılyerleştirildiğiileilgiliolabilir Dengesi iyi sağlanmış tencereler derin tabaklarla ocağ...

Page 25: ...akbelirlediğiyerlere ya da konuyla ilgili ulusal düzenlemelerin mevcut olduğu durumlarda benzer tipte yeni bir ürün aldığınız satıcılara verebilirsiniz Belli başlı tüm beyaz eşya üreticileri kullanılmayan cihazların toplanması ve imha edilmesi için öngörülen sistemlerin oluşturulması ve idaresi konusunda faaliyet göstermektedir Tasarruf ve çevreye saygı Yiyeceklerinizi kapakları iyice oturan kapal...

Page 26: ...alar doğru şekilde monte edilmiş Ocağın yakında hava akımı olabilir Alev emniyet aygıtına sahip olan versiyonlarda yanık kalmıyor Aşağıdaki durumları kontrol ediniz Düğmeye tamamen basılmamış olabilir Emniyet donanımının devreye girmesi için düğme yeterince basılı tutulmamış olabilir Brülörünemniyetdonanımınınkarşısınagelengazçıkışdelikleritıkanmış Brülör minimum pozisyonunda yanık kalmıyor Aşağıd...

Page 27: ...GB 27 ...

Page 28: ...28 GB 195145626 00 05 2016 XEROX FABRIANO Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www hotpoint eu ...

Reviews: