The appliance is fitted with an adjustable, "L" shaped
connector and a gasket for the attachment to the gas supply.
Should this connector have to be turned, the gasket must be
replaced (supplied with the appliance).
The gas feed connector to the appliance is a threaded,
male 1/2" connector for round gas pipe.

Gas Connection to Flexible Steel Pipe
The gas feed connector to the appliance is a threaded,
male 1/2" connector for round gas pipe. Only use pipes,
tubes and gaskets that comply with current safety codes.
The maximum length of the flexible pipes must not exceed
2000 mm. Once the connection has been made, ensure
that the flexible metal tube does not touch any moving
parts and is not crushed.

Check the Seal
Once the appliance has been installed, make sure all the
connections are properly sealed, using a soapy water
solution. Never use a flame.

Electrical Connection
The cooktops fitted with a tripolar electrical supply cord
are designed to be be used with alternating current
according to the indications on the rating plate located
under the cooktop. The earthing wire can be identified by
its yellow-green colour.
In the case of installation over a built-in electric oven,
the electrical connections for the cooktop and oven
should be independent, not only for safety purposes, but
also to facilitate removal of one or both in the future.

Electrical Connection for Gas Cooktop
Fit the supply cord with a standard plug for the demand
rate indicated on the rating plate or connect it directly to
the electrical mains. In the latter case, a single pole switch
must be placed between the appliance and the mains,
with a minimum opening between the contacts of 3 mm in
compliance with current safety codes (the earthing wire
must not be interrupted by the switch). The power supply
cord must be positioned so that it does not reach a tem-
perature in excess of 50°C above room temperature at
any point.
Before making the actual connection, make sure that:

The fuse and electrical system can withstand the load
required by the appliance;

That the electrical supply system is equiped with an
efficient earth hook-up according to the norms and
regulations prescribed by law;

That the plug or switch is easily accessible.

Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow

- Earth

Blue

- Neutral

Brown

- Live

As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:

Connect the Green & Yellow wire to the terminal marked

E” or 

 or coloured Green or Green & Yellow.

Connect the Brown wire to the terminal marked “L” or
coloured Red.
Connect the Blue wire to the terminal marked “N” or
coloured Black.

Adapting the Cooktop for Different Types of Gas
To adapt the cooktop to a different type of gas than that
for which it was designed, (see the sticker under the hob
or on the packaging), the burner nozzles must be changed,
as follows:

Remove the pan supports and slide the burners out of
the cooktop.

Unscrew the nozzles using a 7mm socket wrench and
replace them with those for the new type of gas. (See
table 1, “Burner and Nozzle Specifications”).

Reassemble the parts following the instructions in
reverse order.

On completing the operation, replace the old rating label
with the one showing the new type of gas; the sticker
is available from our Service Centres.

If the gas pressure is different than that prescribed, a
pressure regulator must be installed at the source, in
compliance with national standards governing the use of
piped gas regulators.

Regulation of Air Supply to the Burner
The burners do not need a primary air regulator.

Minimum Regulation
Minimum regulation.

Turn the gas valve to minimum.

Remove the knob and turn the regulator screw
(positioned either on the side of the top or inside the
shaft) clockwise until the flame becomes small but
regular.

N.B.: In the case of liquid gas, the regulation screw must
be fully screwed in (clockwise).

Make sure that, when the knob is turned rapidly high
to low, the flame does not go out.

In the event of a malfunction on appliances with the
security device (thermocouple) when the gas supply
is set at minimum, increase the minimum supply levels
using the regulator screw.

Once the adjustment has been made, apply sealing wax,
or a suitable substitute, to the old seals on the by-pass.

Summary of Contents for PH 631 MS

Page 1: ...installation et l emploi 16 Inbouw kookvlakken 60 Gebruiksaanwijzingen voor de plaatsing en gebruik 24 Encimera empotrable 60 Instrucciones para la instalación y uso 31 Placas de encastre 60 Instruções para a instalação e o uso 38 EINBAU KOCHMULDE 60 Informationen für installation un gebrauch 45 PH 640 M PH 640 MS PH 640 MS T PH 640 MS R PH 640 M IB PH 640 MS IB PH 631 M PH 631 MS PH 631 MS R ...

Page 2: ...l bruciatore prescelto può essere regolato dalla manopo la corrispondente come segue Spento Massimo Minimo Per accendere uno dei bruciatori avvicinare allo stes so una fiamma o un accenditore premere a fondo e ruotare la manopola corrispondente in senso antiorario fino alla posizione di massima potenza Nei modelli dotati di dispositivo di sicurezza F è ne cessario mantenere premuta la manopola per...

Page 3: ... e si ungono con un pò d olio quando sono an cora tiepide l acciaio inox può rimanere macchiato se a contatto per lungo tempo con acqua fortemente calcarea o con detergenti aggressivi contenenti fosforo Si consiglia di sciacquare abbondantemente ed asciugare dopo la pulizia E inoltre opportuno asciugare eventuali traboc chi d acqua Ingrassaggio dei rubinetti Con il tempo può verificarsi il caso di...

Page 4: ...ulla targa matri cola La sicurezza elettrica di questo apparecchio è assicu rata soltanto quando lo stesso è correttamente colle gato ad un efficiente impianto di messa a terra come previsto dalle vigenti norme di sicurezza Trattandosi di fonti di pericolo evitare che bambini e incapaci abbiano contatti con i comandi e l apparecchio in genere gli imballaggi sacchetti polistirolo chiodi ecc l appar...

Page 5: ...essere accidentalmente ostruito Per gli apparecchi pri vi sul piano di lavoro del dispositivo di sicurezza per assenza di fiamma le aperture di ventilazione debbo no essere maggiorate nella misura del 100 con un minimo di 200cm Fig A Ovvero in maniera indiret ta da locali adiacenti dotati di un condotto di ventila zione con l esterno come sopra descritto e che non siano parti comuni dell immobile ...

Page 6: ...n forno da incasso senza ventilazione forzata di raffreddamento per consentire un adeguata areazione all interno del mobile vanno ga rantite delle prese d aria di ingresso e di uscita Possibili esempi di montaggio sono illustrati nelle figure sottostanti Collegamento gas Il collegamento dell apparecchio alla tubazione o alla bom bola del gas dovrà essere effettuato come prescritto dalle Norme UNI ...

Page 7: ...tta caratteristiche l impianto di alimentazione sia munito di efficace col legamento a terra secondo le norme e le disposizioni di legge la presa o l interruttore omnipolare siano facilmente raggiungibili con il piano installato N B non utilizzare riduzioni adattatori o derivatori in quan to essi potrebbero provocare riscaldamenti o bruciature Adattamento ai diversi tipi di gas Per adattare il pia...

Page 8: ... 73 23 CEE del 19 02 73 Bassa Tensione e successi ve modificazioni 89 336 CEE del 03 05 89 Compatibilità Elettromagne tica e successive modificazioni 90 396 CEE del 29 06 90 Gas e successive modificazioni 93 68 CEE del 22 07 93 e successive modificazioni Tabella 1 Gas liquido Gas naturale Gas città Bruciatore Diametro mm Potenza termica kW p c s By pass 1 100 mm Ugello 1 100 Portata g h Ugello 1 1...

Page 9: ...r press the knob all the way in and turn in the counter clockwise direction to the High setting On those models fitted with a safety device F the knob must be pressed in for about 6 seconds until the device that keeps the flame lighted warms up On those models fitted with an ignitor D the E ignition button identified by the symbol must first be pressed and then the corresponding knob pushed all th...

Page 10: ...teel can be stained if it remains in contact with highly calcareous water or aggressive detergents containing phosphorous for an extended period of time It is recommended that these parts be rinsed thoroughly with water and then dried well It is also a good idea to clean up any spills Greasing the Gas Valves Over time the gas valves may stick or become difficult to turn If this is the case the mus...

Page 11: ...ce centers authorized by the manufacturer in the following cases When in doubt about the condition of the appliance after having removed the packing Damage to or replacement of the power supply cord In the case of a breakdown or malfunction ask for original spare parts It is recommended that you follow the guidelines below Only use the appliance to cook food avoiding all other uses The burner does...

Page 12: ... accidentally blocked Those appliances which are not fitted with a safety device to prevent the flame from accidentally going out must have a ventilation opening twice the size otherwise required i e a minimum of 200cm Fig A Otherwise the room can be vented indirectly through adjacent rooms fitted with ventilation ducts to the outside as described above as long as the adjacent rooms are not shared...

Page 13: ...installing the cooktop above a built in oven without forced ventilation ensure that there are air inlets and outlets for ventilating the interior of the cabinet adequately Gas Connection for Cooktop The cooktop should be connected to the gas supply by an authorized installer During installation of this product it is essential to fit an approved gas tap to isolate the supply from the appliance for ...

Page 14: ...equiped with an efficient earth hook up according to the norms and regulations prescribed by law That the plug or switch is easily accessible Important the wires in the mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your ...

Page 15: ...5 1 65 0 4 30 28 64 120 118 96 157 Auxiliary Small A 55 1 00 0 4 30 28 50 73 71 71 95 Triple Crown TC 130 3 25 1 3 60 57 91 236 232 133 309 Supply pressures Nominal mbar Minimum mbar Maximum mbar 28 30 20 35 37 25 45 20 17 25 At 15 C and 1013 mbar dry gas Propane P C S 50 37 MJ kg Butane P C S 49 47 MJ kg Table1 For Hungary G 20 G 25 1 G 30 Burner By pass 1 100 mm Thermal power kW Nozzle 1 100 mm ...

Page 16: ...ns et des puissances différentes Choisissez en un en fonction du diamètre de la casserole utilisée Pour le réglage du brûleur choisi servez vous de la ma nette correspondante comme suit Eteint Maximum Minimum Pour allumer un brûleur approchez une flamme ou un allume gaz appuyez à fond sur la manette correspondante et tournez la dans le sens contraire des aiguilles d une montre jusqu à la position ...

Page 17: ... du gaz ne soient pas bouchés nettoyez les plaques électriques avec un chiffon humide et graissez les avec un peu d huile quand elles sont encore tièdes des taches peuvent se former sur l acier inox si ce dernier reste trop longtemps au contact d une eau fortement calcaire ou de détergents agressifs contenant du phosphore Il est conseillé de rincer abondamment et d essuyer après le nettoyage Il va...

Page 18: ... par le fabricant dans les cas suivants en cas de doute sur le bon état de l appareil lors de son déballage endommagement ou remplacement du cordon d alimentation en cas de panne ou de mauvais fonctionnement exigez des pièces détachées originales Il peut arriver que la table ne fonctionne pas ou ne fonctionne pas très bien Avant d appeler le service après vente voyons ensemble que faire Vérifiez a...

Page 19: ... à l intérieur des bâtiments d habitation et de leur dépendances Norme DTU P45 204 Installations de gaz anciennement DTU n 61 1 installations de gaz Avril 1982 additif n 1 Juillet 1984 Règlement sanitaire départemental Positionnement Cet appareil peut être installé et fonctionner seulement dans des locaux qui sont aérés en permanence selon les prescriptions des Normes Pour la France selon les Norm...

Page 20: ... en train d utiliser placé de façon à ne pas être sujet à l action directe des sources de chaleur fours feux de bois poêles etc pouvant lui faire atteindre des températures dépassant 50 C Installation des tables à encastrer Les tables à gaz et mixtes sont prévues avec un degré de protection contre les surchauffes excessives du genre X on peut par conséquent les installer à côté de meubles dont la ...

Page 21: ...ne contrainte à l appareil La rampe d alimentation de l appareil est munie d un raccord en L orientable avec joint d étanchéité S il est nécessaire de faire tourner le raccord il faut impérativement remplacer le joint d étanchéité fourni avec l appareil Le raccord d entrée du gaz à l appareil est fileté G 1 2 taraud cylindrique Raccordement du tuyau flexible en acier Le raccord d entrée du gaz à l...

Page 22: ...s opérations dans le sens inverse enfind opération remplacezl ancienneétiquettedecalibrage par la nouvelle correspondant au nouveau gaz utilisé que vous trouverez dans nos centres de Service Après vente Uniquement pour la Belgique en fin d opération remplacez l ancienne étiquette de réglage par celle correspondant au nouveau gaz utilisé qui se trouve dans le sachet des injecteurs fournis avec le p...

Page 23: ...cteur 1 100 Débit g h Injecteur 1 100 Débit l h Nom Red 1 mm mm G20 Rapide Grand R 100 3 00 0 7 41 39 86 218 214 116 286 Rapide Réduit RR 100 2 60 0 7 41 39 80 189 186 110 248 Semi Rapide Moyen S 75 1 65 0 4 30 28 64 120 118 96 157 Auxiliaire Petit A 55 1 00 0 4 30 28 50 73 71 71 95 Triple Couronne TC 130 3 25 1 3 60 57 91 236 232 133 309 Pression de alimentation Nominale mbar Minimum mbar Maximum...

Page 24: ...viale Aristide Merloni 47 60044 Fabriano tel 0732 6611 telex 560196 fax 0732 662954 www Merloni com Nuovo piano incasso 60 06 99 195016904 06 Xerox Business Services Docutech ...