Servicing Notes
Drum Thumping Noise
When first started, it is normal for the drum to make a thumping noise for approximately 2 minutes,
while the drum support wheels centralise to the load conditions.
No Motor Action
When diagnosing the cause of no motor action, it should be remembered that one of the door
switches is in the motor supply.
F15
Upper element is on when
it should be off.
•
Check security of module connector J4;
•
Check connector for signs of shorting due to moisture;
•
Check heater elements and wiring;
•
Replace module (F15 would normally be caused by a
faulty module).
F16
Not used.
F17
Master Relay contacts
welded closed.
•
Replace module.
Operation of the float switch:
After continuing to tumble and dry for a further
one minute, the dryer will turn off the heater
and cool tumble for a further 10 minutes -
before displaying the Fault Code H20, the
Empty Water light flashing the Start/Pause
button flashing Orange.