22 of 36
Service Manual UK
Indesit
Company
English
FAULT CODES
In the event of a fault being detected by the
electronics, a code will appear in the LCD
display.
These codes are listed in the following table.
Please Note:
•
Components with a low resistance to
Earth may cause erroneous faults or
loss of the display.
•
Always check relevant wiring and
connector blocks security
before
considering replacing the modules.
Code
Fault
Check for Corrective Action
F01
Motor runs continually
Check module connection J3 for sign of shorting.
Replace Module.
F02
No Drum Motor Action
Check security of module connection J3.
Check motor for open circuit.
F03
Front NTC open or short
circuit
Check security of module connection J12.
Check Resistance of NTC (see page 15 for reading).
F04
No pump
Check security of module connector J5.
Check float operation & switch.
Check pump / wiring for open circuit
F05
Pump continually running
Check security of wiring module J5.
Module fault - Replace module.
F06
Not used
F07
Not used
F08
Compressor fault
Check security of module connection J11 & J4.
Check wiring to compressor via capacitor.
Check compressor for open circuit.
Relay fault on module - replace module.
F09
Error with set up file
Check connection between interface and control module J9
Check programme file and re - load as required.
EEPROM fault on module - Replace module.
F10
Not used
F11
Same as
F04
continued...
Example of a Fault Code
All 4 options button lights and the Start/Pause
light will flash when a Fault Code is displayed.